CCS800 | Service manual | Chapter 7 | Diagnostics and faultfinding
7.3.10

Recorder-in to Line-out measurement

Remove the interconnections of REC-IN-L and REC-IN-R and connect successively a sine-wave generator to the REC-IN-
L and REC-IN-R connector. Measure the output signal at the LINE-OUT connector.
NOTE: be sure that the gain control potentiometer (R200) of the recorder input is set to the middle position.
Input setting G1: M121 & M122 related to M124 (GND), see table below.
Settings for G1
Amplitude
Nominal level
-20dBV (100mV
Maximum level
+5dBV (1.78V
Bandwidth
-20dBV (100mV
Bandwidth
-20dBV (100mV
Reference:
M119, R300
Bosch Security Systems | 2005-01| 3922 880 21112
Frequency
)
1kHz
rms
)
1 kHz
rms
)
125 Hz
rms
)
12.5 kHz
rms
See Ch. 13.6
Measurement results for A1
Amplification
-16.5dBV ± 2dB (85dB SPL)
+9.5dBV ± 2dB (110dB SPL)
-0.5dB ± 1dB related to nom. level at 1kHz
-1dB ± 1dB related to nom. level at 1kHz.
en | 29