Download Print this page
iOptron SkyGuider Pro Quick Start Manual

iOptron SkyGuider Pro Quick Start Manual

How to rotate or replace a polar scope
Hide thumbs Also See for SkyGuider Pro:

Advertisement

Quick Links

This instruction is not for polar scope alignment, nor for 
polar  scope  reticle  adjustment.  This  is  for  those  who 
want  to  rotate  the  polar  scope  to  align  the  12  o'clock 
mark to the DEC bracket orientation.   
Tool needed: 1.5mm, 2mm and 2.5mm Allen wrenches, 
Phillips screw driver 
1. Loosen  two  screws  at  the  front  of  the  mount  and 
two  others  on  the  top  of  a  SkyGuider  Pro  main 
board cover and remove the black cover. 
2. Remove  the  black  plastic  cover.  Remember  how 
wires are wrapped. 
Wire wrapping 
3. Pull the belt off the worm pulley. Then remove the 
belt from the small motor pulley.  
4. Remove the small motor pulley from the motor axle 
by release a set screw using a 1.5mm allen wrench. 
If  the  set  screw  is  not  accessible,  you  may  gently 
turn  the  black  encoder  wheel  with  your  finger  to 
rotate the motor axle. You need be very careful not 
to  bend  the  black  ticks!    It  may  also  need  a  lot  of 
turns. 
How to Rotate or Replace a SkyGuider Pro Polar Scope (9/1/2017) 
 
 
5. Disconnect both motor and battery cables. 
 
6. Remove the motor by release two Phillips screws. 
7. Remove  two  screws  that  secure  the  circuit  board. 
Gently  pull  the  circuit  board  out  of  the  mount 
compartment.  There  is  a  LED  connection 
underneath. 
8. Disconnect the polar scope LED cable. 
 
 
 
 
 
 

Advertisement

loading

Summary of Contents for iOptron SkyGuider Pro

  • Page 1 How to Rotate or Replace a SkyGuider Pro Polar Scope (9/1/2017)  This instruction is not for polar scope alignment, nor for  polar  scope  reticle  adjustment.  This  is  for  those  who  want  to  rotate  the  polar  scope  to  align  the  12  o’clock  mark to the DEC bracket orientation.    Tool needed: 1.5mm, 2mm and 2.5mm Allen wrenches,  Phillips screw driver  1. Loosen  two  screws  at  the  front  of  the  mount  and  two  others  on  the  top  of  a  SkyGuider  Pro  main   ...
  • Page 2 9. Remove polar scope cover and base.      10. Release  RA  Clutch  Disk  slightly  so  the  polar  scope  13. Put  the  battery  back  into  the  compartment.  can be rotated.   Connect  the  LED  cable  to  the  board  first.  While  install board back into the compartment, make sure  that  the  LED  cable  is  not  jammed  between  the  board and the case. ...
  • Page 3 21. Now  follow  the  Polar  Scope  Alignment  instruction  to check if the polar scope is aligned to the RA axis.  If it is not, follow the instruction to adjust it.  http://www.ioptron.us/Support/SGP_PolarScopeAlign.pdf    16.  Wrap  the  belt  over  both  pulleys  and  slide  motor  pulley  onto  the  motor  axle,  very  carefully!  Make  sure  the  belt  is  not  jammed  under  the  large  worm ...