Toro Lynx SmartHub Installation And User Manual page 35

Table of Contents

Advertisement

Menu: DB Monitor
Menu: Event Codes
Menu: Decoder
Communications
Menu: Decoder
Diagnostics
Menu: Radio Tx Chars
Displays the voltage and amperage of the
daughterboards attached to the motherboard,
as well as the amps for L1 and L2 (black and
white respectively) terminals.
Displays the SmartHub's Event Code log. You
can clear the log from this option. Navigate
to the Clear field using the Down arrow
, select Yes using the Input Dial
press the Down arrow
Displays real-time communication data
between the TM and a decoder.
This command allows the user to run
diagnostic tests that send messages to decoders
and modules. The faceplate will show the last
test performed at the TM. The tests include:
communication (pictured)
solenoid (pictured)
LSM voltage
LSM amps
LSM version
LSM Hardware Errors
LSM Grp02 Info
LSM Grp16 Info
LSM Group Ping
Group Volts
Group Amps
Group Errors
Group Sta's On
LSM Grp Charge Fail
Cable Resistance (pictured) *
Decoder Output *
Decoder Version *
DBoard Output *
DBoard Version *
Note: Tests marked with an asterix (*)
are for GAC only.
This menu item transmits numerical sequences
to another radio for troubleshooting purposes.
Lynx® SmartHub Installation and User Guide
Menu: DB Monitor
Volts
Amps
L1
L2
Menu: Event Codes
Clear log: No
Last Code: 131, 005
and
01/12/12, 09:37:20
to activate.
Menu: Decoder Comm.
Sent: Rd Flow Bd1
Resp: Ok
Total bad Resp: 000
Total Timeouts: 000
Clear Totals
Menu: Decoder Diag.
Communication
Brd 01, Sta 001
Press
34.78V 0.14A
Status: 03 DONE
Menu: Decoder Diag.
Solenoid
Brd 01, Sta 001
Press
Result: 00 Out1 OK
Status: 03 DONE
Menu: Decoder Diag.
Cable Resistance
Brd 01, Sta 001
Press
1.25V/0.31A = 4.1Ω
Status: 03 DONE
DB1
DB2
38.8V
None
0.000A
0.000A
0.000A
: No
to start
to start
to start
35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents