Lynx® SmartHub Installation and User Guide
Alarm Conditions
All of the Alarm Conditions, when active, toggle back and forth between the two message states below.
Thermal Alarm
D1 Thermal
D2 A=0.500
Hold Entr to Clr
D2 A=0.500
Amp Limited Alarm
D1 Amp Limited
D2 A=0.500
D1 A=1.100
D2 A=0.500
Phase Current
Imbalance Alarm
D1L1 High Amp
D2 A=0.500
D1L1 A=0.750
D2 A=0.500
The display difference between the High Current Alarm and Phase Current Imbalance Alarm is subtle:
Notice the two-character difference in the display on the first line:
"D1" (High Current Alarm) vs. "D1L1" (Phase Imbalance).
Clear Alarms
To clear any of the above alarm conditions, hold ENTER to clear the alarm.
38
Shuts off and disables daughterboard indefinitely.
Motherboard LCD toggles alarm and instruction on how to re-enable
the daughterboard.
Affected daughterboard's alarm LED blinks on and off.
Triggered when individual daughterboard's load current is above 1.0 Amps.
Does NOT shut off or disable daughterboard.
Motherboard LCD toggles alarm and instruction on how to clear the alarm.
Affected daughterboard's alarm LED blinks on and off.
Triggered when load current of one wire is 2x higher than the opposite wire
for a minimum 20 seconds.
20 second timer is reset when load current of one wire is no longer 2x higher.
Does NOT shut off or disable daughterboard.
Motherboard LCD toggles alarm and instruction on how to clear the alarm.
Affected daughterboard's alarm LED blinks on and off.