Figure 9
Station 3
White Wire: Connect to one of Station 3's solenoid wires.
Station 2
Yellow Wire: Connect to one of Station 2's solenoid wires.
Station 1
Violet Wire: Connect to one of Station 1's solenoid wires.
Valve Common
Brown Wire: Connect to one of the wires from
each of the four solenoids.
Red Power/Communication Wire
Black Power/Communication Wire
The maximum communication wire length
between the decoder module and the
solenoid is 575' (175m).
Recommended Cable for Decoder-to-
Solenoid is a Solid Copper, 2-Conductor,
Direct Burial cable.
To easily identify stations for
troubleshooting, install wires with the same
color code as the station wires.
Recommended Cable for Controller-to-Decoder is 14 AWG, Solid
Copper, Jacketed 2-Conductor, Direct Burial cable.
Black
Black
Station 4
Orange Wire: Connect to one of Station 4's
solenoid wires.
Each station can activate up to 2 solenoids.
(See valve compatibility for details.)
AC Solenoid
Each output circuit can accommodate up to
125 Decoder Modules.
Daughterboard
Output
Output
Circuit #1
Circuit #2
When possible, install the
decoder module in a valve
box for ease of service.
1-Station
Decoder
Module
Out to additional
Station Wire
decoder modules
Valve Common Wire
Maximum communication wire length
between the controller and the farthest
decoder is 2,072m (2.5mm
).
2