Before you start

Assembly

Read the operator's manual carefully to ensure that you assemble the product correctly.
Never perform maintenance or assembly procedures with engine running.
Using a product that has been incorrectly assembled could lead to an accident or serious injury.
Install blower pipes
1. Blower pipe
1. Blower pipe
Remove blower pipes
WARNING
2. Round straight nozzle
Before you start
1.
Stand unit upright on blower base.
2.
Align large locking ribs (A) on curved blower pipe with pipe
lock (B) in fan case. Slide curved blower pipe into fan case
until a clicking sound is heard.
∗ Do not assemble the opposite end of the curved blower pipe
to the fan case.
3.
Align tabs (C) with grooves (D) and slide the round straight
nozzle over the blower pipe until there is light resistance. Do
not force connection.
4.
Hold the blower pipe, and turn the round straight nozzle
clockwise, engaging positive locking channels until connec-
tion is firm. Do not force connection.
NOTE
Blower use will eventually loosen pipe connections. Exclusive
positive locking system allows pipes to be tightened. If loosen-
ing occurs, remove the round straight nozzle and install ac-
cording to instructions 3 & 4.
1.
Insert screwdriver (E) into hole located near lock symbol (F)
to release pipe lock.
2.
Pull pipes out of fan cace.
3.
Remove screwdriver.