Torque Values; Pluggable Transceiver Specifications; Console Port Pinout Assignments; Regulatory Compliance - Enterasys A4H124-24FX Hardware Installation Manual

Fast ethernet switch
Table of Contents

Advertisement

Table A-6 STK-RPS-150CH2 Power Supply Connector Pin Functions
Pin Number
1
2
3
4
5
6
7

Torque Values

Table A-7
threaded fastener machine screws and bolts.
Table A-7 Recommended Torque Values by Screw Size
English
2 – 56
4 – 40
6 – 32
8 – 32
10 – 32
1/4 – 20

Pluggable Transceiver Specifications

For SFP transceiver specifications, refer to the datasheet at
http://www.enterasys.com/products/transceivers-ds.pdf.

Console Port Pinout Assignments

Refer back to

Regulatory Compliance

This product meets the safety, electromagnetic compatibility (EMC), and environmental
requirements listed in
Function
Ground
No connection
12 Vdc Output
12 Vdc Output
12 Vdc Output
12 Vdc Output
Ground
describes the recommended torque values to use when installing the using standard
Screw Size
Metric
N/A
N/A
1.5
2.5
3.5
4.5
5
6.5
Figure 2-12
on page 2-18 for information about console port pinout assignments.
Table
A-8.
Pin Number
8
9
10
11
12
13
14
Torque in Pounds
-%5
Nominal
1.42
1.5
2.85
3.0
4.75
5.0
8.55
9.0
17.10
18.0
30.40
32.0
63.65
67.0
Enterasys A4 Fast Ethernet Switch Hardware Installation Guide A-5
Torque Values
Function
Ground
No connection
No connection
Status 1
Status 2
Power good
Ground
Bit Size
+%5
1.57
0
3.15
0
5.25
0/1
9.45
1
18.90
2
33.60
2
70.35
3