Position Projection Alarm; Distance/Resistance/Interference - La Crosse Technology 616-143V2 Faqs

Table of Contents

Advertisement

POSITION
 Mount outdoor temperature outdoor sensors vertically.
 Protect the outdoor sensor from standing rain or snow and from the overhead sun, which can cause it
to read incorrectly.
 Mounting under an eave or deck rail works well.
 If you choose, you can construct a small roof or box for the outdoor sensor. Be sure a box has vents.
 Mount the outdoor sensor on the North side where to prevent sun from causing incorrect readings.
 Mount at least 6 feet in the air for a strong RF (radio frequency) signal.
 Outdoor sensors are water resistant, not waterproof.
 Avoid more than one wall between the outdoor sensor and the projection alarm.
 The maximum transmitting range in open air is over 330 feet (100 meters).
 Obstacles such as walls, windows, stucco, concrete and large metal objects can reduce the range.
 Do not mount near electrical wires, transmitting antennas or other items that will
signal.
 RF (radio frequency) signals do not travel well through moisture or dirt.
 Do not mount the outdoor sensor on a metal fence. This significantly reduces the effective range.
MOUNT
Option 1:
 Install one mounting screw (not included) into a wall.
 Place the outdoor sensor onto the screw (hanging hole on the backside).
 Gently pull down to lock the screw in place.
Option 2:
 Insert the mounting screw through the front of the outdoor sensor and into the wall.
 Tighten the screw to snug (do not over tighten).

Position Projection Alarm

 The projection alarm has a wide base to sit on a desk or table.
 Place within
range
of the outdoor sensor.
 The maximum transmitting range in open air is 330 feet (100 meters).
 Obstacles such as walls, windows, stucco, concrete and large metal objects can reduce the range.
 Choose a location 6 feet or more from electronics such as cordless phones, wireless gaming
systems, televisions, microwaves, routers, baby monitors, etc., which can prevent signal reception.
 Be aware of electrical wires and plumbing within a wall. This will interfere with RF (radio frequency)
signal reception.

Distance/Resistance/Interference

Distance:
 The maximum transmitting range in open air is over 330 feet (100 meters) between the outdoor
sensor and the projection alarm. This range is in open air with ideal conditions.
 Consider what is in the signal path between the projection alarm and the outdoor sensor.
 Avoid placing electronic in the signal path between the projection alarm and the outdoor sensor.
Resistance:
 Obstacles such as walls, windows, stucco, concrete and large metal objects can reduce the range.
 When considering the distance between the outdoor sensor and the projection alarm (330 feet open
air), cut that distance in half for each wall, window, tree, bush or other obstruction in the signal path.
 Closer is better.
 Windows reflect the RF (radio frequency) signal.
 Metal absorbs the signal and reduces the range.
 Stucco has a metal mesh that absorbs the signal.
 Do not mount the outdoor sensor on a metal fence. This significantly reduces the effective range.
Interference:
 Consider items in the signal path between the outdoor sensor and the projection alarm.
La Crosse Technology, Ltd.
www.lacrossetechnology.com/support
interfere
with the
Page 5