j. Press the Back key once, the following display
appears:
14—1* Mains On/Off
14—2* Reset Functions
k. Press ▼ (Down Arrow) twice, the following display
appears:
14—4* Energy Optimising
14—5* Environment
Motor
Motor
Voltage
Option
P/N
208/230V HD56FR233 HK30WA370 131L9795
STD
460V
HD56FR463 HK30WA376 131L9863
575V
HD56FR579 HK30WA382 131N0225
208/230V HD56FR233 HK30WA370 131L9795
MID
460V
HD56FR463 HK30WA376 131L9863
575V
HD56FR579 HK30WA382 131N0225
208/230V HD58FE654 HK30WA371 131L9796
HIGH
460V
HD58FE654 HK30WA377 131L9864
575V
HD58FE577 HK30WA383 131N0227
START
DELAY
(SEC)
Motor
Voltage
1-71
Option
208/230V
2.0
STD
460V
2.0
575V
2.0
208/230V
2.0
MID
460V
2.0
575V
2.0
208/230V
2.0
HIGH
460V
2.0
575V
2.0
RAMP UP
TIME
(SEC)
Motor
Voltage
3-41
Option
208/230V
10.00
STD
460V
10.00
575V
10.00
208/230V
10.00
MID
460V
10.00
575V
10.00
208/230V
10.00
HIGH
460V
10.00
575V
10.00
Table 22 — VFD Unit Parameters - 50LC 07 Units
REGIONAL
VFD
VFD
Carrier
Mfr
P/N
P/N
MIN
SPEED
MOTOR
FLYING
FOR
THERMAL
START
FUNCTION
PROTECTION
(Hz)
1-73
1-82
1-90
[1]
1.0
[4]
[1]
1.0
[4]
[1]
1.0
[4]
[1]
1.0
[4]
[1]
1.0
[4]
[1]
1.0
[4]
[1]
1.0
[4]
[1]
1.0
[4]
[1]
1.0
[4]
RAMP DOWN
CURRENT
TIME
LIMIT
(SEC)
3-42
4-18
10.00
100%
10.00
100%
10.00
100%
10.00
100%
10.00
100%
10.00
100%
10.00
100%
10.00
100%
10.00
100%
l. Press OK, the following display appears:
14-50 RFI Filter
[1] On
m. Press OK to highlight the number in the bracket and
use the ▲ and ▼ (Up and Down Arrow) keys to
select [0]. Press OK again to set the selected value.
13. To Complete Reprogramming:
a. Press the Auto On key before disconnecting the VFD
Remote Keypad from the variable frequency drive.
GRID
MOTOR
SETTINGS
TYPE
POWER
0-03
0-06
1-20
[1]
[102]
[9]
[1]
[122]
[9]
[1]
[132]
[9]
[1]
[102]
[9]
[1]
[122]
[9]
[1]
[132]
[9]
[1]
[102]
[10]
[1]
[122]
[10]
[1]
[132]
[11]
3-10 [0] 3-10 [1] 3-10 [2] 3-10 [3] 3-10 [4] 3-10 [5] 3-10 [6] 3-10 [7]
0%
66.50% 66.50%
0%
66.50% 66.50%
0%
66.50% 66.50%
0%
66.50% 66.50%
0%
66.50% 66.50%
0%
66.50% 66.50%
0%
66.50% 66.50%
0%
66.50% 66.50%
0%
66.50% 66.50%
TERMINAL 18
DIGITAL
INPUT
5-10
[8]
[8]
[8]
[8]
[8]
[8]
[8]
[8]
[8]
49
MOTOR
MOTOR
CURRENT
FREQUENCY
VOLTAGE
(MUST-HOLD
(Hz)
1-22
1-23
230
60
460
60
575
60
230
60
460
60
575
60
230
60
460
60
575
60
PRESET
REFERENCE
100%
100%
0%
100%
100%
0%
100%
100%
0%
100%
100%
0%
100%
100%
0%
100%
100%
0%
100%
100%
0%
100%
100%
0%
100%
100%
0%
TERMINAL 19
TERMINAL 27
DIGITAL
DIGITAL
INPUT
INPUT
5-11
5-12
[16]
[17]
[16]
[17]
[16]
[17]
[16]
[17]
[16]
[17]
[16]
[17]
[16]
[17]
[16]
[17]
[16]
[17]
MOTOR
MOTOR
NOMINAL
SPEED
AMPS)
(RPM)
1-24
1-25
5.8
1695
2.9
1690
3.1
1690
5.8
1695
2.9
1690
3.1
1690
9.2
1735
4.2
1735
4.9
1710
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
TERMINAL 29
DIGITAL
INPUT
5-13
[18]
[18]
[18]
[18]
[18]
[18]
[18]
[18]
[18]