Carrier WeatherExpert 50LC 07 Series Installation Instructions Manual page 3

Single package rooftop cooling only with r-410a refrigerant
Table of Contents

Advertisement

Position:
1
Example:
5
Unit Heat Type
50 - Electric Cooling/Heating
Packaged Rooftop
Model Series - WeatherExpert
LC - Ultra High Efficiency
Heat Options
0 = Standard - No Electric Heat
D = Low Electric Heat
E = Medium Electric Heat
F = High Electric Heat
Refrig. Systems Options
0 = Three stage cooling capacity control with TXV
A = Three stage cooling capacity control with TXV
and Humidi-MiZer
®
System
Cooling Tons
07 - 6 ton
Sensor Options
A = None
B = RA Smoke Detector
C = SA Smoke Detector
D = RA + SA Smoke Detector
E = CO
2
F = RA Smoke Detector and CO
G = SA Smoke Detector and CO
H = RA + SA Smoke Detector and CO
Indoor Fan Options
1 = Standard Static Belt Drive with VFD controller
2 = Medium Static Belt Drive with VFD controller
3 = High Static Belt Drive with VFD controller
Coil Options: Fin/Tube (Condenser- Evaporator - Hail Guard)
A = Al/Cu - Al/Cu
B = Precoat Al/Cu - Al/Cu
C = E-coat Al/Cu - Al/Cu
D = E-coat Al/Cu - E-coat Al/Cu
E = Cu/Cu - Al/Cu
F = Cu/Cu - Cu/Cu
M = Al/Cu -Al/Cu — Louvered Hail Guard
N = Precoat Al/Cu - Al/Cu — Louvered Hail Guard
P = E-coat Al/Cu - Al/Cu — Louvered Hail Guard
Q = E-coat Al/Cu - E-coat Al/Cu — Louvered Hail Guard
R = Cu/Cu - Al/Cu — Louvered Hail Guard
S = Cu/Cu - Cu/Cu — Louvered Hail Guard
2
3
4
5
6
7
8
0
L
C
D
0
0
7
®
2
2
2
Fig. 1 — 50LC 07 Model Number Nomenclature
9 10 11 12 13 14 15 16 17 18
A
1
A
5
-
0
A
0
Intake / Exhaust Options
A = None
B = Standard Leak Temperature Economizer
E = Standard Leak Enthalpy Economizer
N = Ultra Low Leak Temperature Economizer
R = Ultra Low Leak Enthalpy Economizer
Base Unit Controls
0 = Electro-mechanical Controls
1 = RTU Open Multi-Protocol Controller
4 = SystemVu™ Controller
Design Revision
- = Factory Design Revision
Voltage
1 = 575/3/60
5 = 208-230/3/60
6 = 460/3/60
3
A
0
Packaging
0 = Standard
1 = LTL
Electrical Options
A = None
B = HACR Circuit Breaker
C = Non-Fused Disconnect
D = Thru-The-Base Connections
E = HACR Circuit Breaker
and Thru-The Base Connections
F = Non-Fused Disconnect and
Thru-The-Base Connections
Service Options
0 = None
1 = Unpowered Convenience Outlet
2 = Powered Convenience Outlet
3 = Hinged Panels
4 = Hinged Panels and
Unpowered Convenience Outlet
5 = Hinged Panels and
Powered Convenience Outlet
with Barometric Relief
with Barometric Relief
with Barometric Relief
with Barometric Relief

Advertisement

Table of Contents
loading

Table of Contents