441X
®
STORING
1. Store the machine in a cool, dry place when it is not in use.
Protect it from dust and dirt. Keep it where it can't be
accidentally damaged from construction activities, moving
vehicles, and other hazards.
2. Drain the engine oil and re ll with fresh oil. Run the engine for
about ve minutes to circulate oil to all the parts. See the
ENGINE OPERATION section manual for details on changing
oil.
3. Remove the battery, recharge it, and adjust the electrolyte
level. Store the battery in a dry, dark place.
STACKING
Vantage
®
441X machines cannot be stacked.
ANGLE OF OPERATION
To achieve optimum engine performance the Vantage
should be run in a level position. The maximum angle of operation
for the Perkins
engine is 30 degrees in all directions. When
®
operating the welder at an angle, provisions must be made for
checking and maintaining the oil level at the normal (FULL) oil
capacity. Also the effective fuel capacity will be slightly less than
the speci ed 20 gal. (75.7L).
LIFTING
The Vantage
441X weighs approximately 1553 lbs. (704kg) with
®
a full tank of fuel and 1414 lbs. (641kg) less fuel. A lift bale is
mounted to the machine and should always be used when lifting
the machine.
WARNING
FALLING EQUIPMENT
can cause injury.
Lift only with equipment of adequate lifting
capacity.
Be sure machine is stable when lifting.
Do not lift this machine using lift bale if it is equipped
with a heavy accessory such as trailer or gas cylinder.
Do not lift machine if lift bale is damaged.
Do not operate machine while suspended from lift bale.
------------------------------------------------------------------
HIGH ALTITUDE OPERATION
At higher altitudes, output derating may be necessary. For
maximum rating, derate the welder output in accordance with the
guidelines in Table A.1 below for this engine model from the
manufacturer:
TABLE A.1 PERKINS 404F-E22T
SEA LEVEL
82 kPa
70 kPa
HIGH TEMPERATURE OPERATION
At temperatures above 104°F (40°C), output voltage derating may
be necessary. For maximum output current ratings, derate welder
voltage rating 2 volts for every 21°F (10°C) above 104°F (40°C).
®
441X
COLD WEATHER STARTING:
With a fully charged battery and OW40 oil, the engine should start
satisfactorily down to -20°F (-29C°). If the engine must be
frequently started at or below 0°F (-18°C), it may be desirable to
install cold-starting aides. For engines with common rail injection,
the mixing of petroleum or kerosene and adding of extra low
additives is not permissible. Fuels in accordance with ASTM S975
Grade 1D or DIN EN590-Arctic-Diesel may have no petroleum
added. Allow the engine to warm up before applying a load or
switching to high idle.
Under no conditions should ether or other
starting uids be used with this engine!
------------------------------------------------------------------
A-3
Altitude
Meters
Feet
0
0
1749
5,739
3012
9,882
WARNING
INSTALLATION
Maximum
Horsepower
41
39
37

Advertisement