Replace Brush & Belt
WARNING
To reduce the risk of electric shock, turn power switch o and disconnect plug from
electrical outlet before performing maintenance or troubleshooting checks.
1
Unplug vacuum, turn over and unscrew
six (6) Phillips head screws to remove
the bottom cover. Lift brush straight out.
3
Belt
End Cap
Replace the Brush Roll and Belt by looping the Belt over the motor shaft and the
Brush Roll. Line up the End Caps and pull the brush forward into place. This will
stretch the Belt. Return bottom cover back on and replace the screws.
Clearing a Clog
1
2
Remove the Stretch
Check the Foot Hose on
Hose from the back
the back of your vacuum
of the vacuum by
down towards the bottom.
twisting it to the left.
If necessary, remove the
Remove any debris
screw from the Foot Hose
that may have gotten
and check for clogs.
clogged.
2
Clean debris from Brush Roll. Inspect by
placing on its end and spin. The Brush
Roll should spin freely, multiple times by
one flick. If it doesn't, replace Brush Roll.
Check Belt for wear or cuts and replace
if necessary.
3
Check the air passageway on
the bottom of your vacuum.
Remove the bottom cover and
the brush. Remove any debris.
www.BISSELL.ca
9