Qs2 (Panel Operation Data) - Pioneer PDP-6010FD Service Manual

Plasma display system
Hide thumbs Also See for PDP-6010FD:
Table of Contents

Advertisement

5

9.3.2 QS2 (PANEL OPERATION DATA)

The command QS2 is for acquiring data on the panel's operational information.
Command
Effective Operation
Format
Modes
[QS2]
All operations
Data Arrangement
ECO
1
Power supply status
2
Adjustment flag of the main unit
3
Adjustment-data backup flag
4
"1st PD" data
5
"2nd PD" data
6
Reserved
7
Temperature data (TEMP 1)
8
SD main data
9
SD sub data
10
Operation status induced by SD
11
Reserved
12
HOUR METER
13
MASK indication
14
Still picture detection
15
SCAN protection detection
16
Panel crack detection
17
Address emergency detection
18
Reserved
19
CS
1: Power supply status
P
During power ON
Entering Passive
mode failed during
0
standby
Entering Passive
mode succeeded
1
during standby
2: Adjustment flag of
the main unit
0
Adjustment completed
Adjustment not
1
completed
3: Adjustment-data
backup flag
0
With backup data
1
No backup data
5
6
Function
To acquire data on operations of the panel Return data: 3 (ECO) + 34 (DATA) + 2 (CS) = 39 Byte
Data
Output Example
Length
3 byte
QS2 (fixed)
1 byte
1 byte
1 byte
1 byte
1 byte
3 byte
3 byte
063
1 byte
1 byte
1 byte
3 byte
8 byte
00000437
1 byte
1 byte
7C
1 byte
1 byte
1 byte
4 byte
2 byte
4, 5: PD data
0
No PD data
1
Not used
2
POWER
3
SCAN
4
SCN-5V
5
Y-DRV
6
Y-DCDC
7
Y-SUS
8
ADRS
9
X-DRV
A
X-DCDC
B
X-SUS
C
DIG-DCDC
D
Not used
E
Not used
F
UNKNOWN
PDP-6010FD
6
7
8: SD main data
0
No SD
0
1
SQ_LSI communication error
0
2
MDU-IIC communication error
0
3
Abnormally in RST2
0
4
TEMP
0
∗∗
9-1: SD-Sub (SQ_LSI)
0
No SD-Sub data
0
1
Communication error
0
2
Drive stop
0
3
BUSY
0
4
Version mismatching (H/S)
5
Version mismatching (M/S)
0
9-2: SD-Sub (MDU-IIC)
0
No SD-Sub data
1
EEPROM
2
BACKUP
3
DAC1
4
DAC2
9-3: SD-Sub (TEMP)
0
No SD-Sub data
1
TEMP1 high temperature
2
TEMP1 low temperature
10: Operation status
induced by SD
0
Normal
1
Relay-off completed
During warning
2
indication
13: MASK indication
0
MASK-OFF
1
MASK-ON
14 to 17: Detection of Each Protection function
0
Normal operation
1
At detection of protection operation
7
8
Remarks
155
8
A
B
C
D
E
F

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents