5
Recovery flowchart (2-1)...Changing the VOL YNOFS3/4/1 setting voltage
[From the Main flowchart (2)]
RST MASK 16 (Green 1023+)
Set VOL YNOFS1 to the tentative setting value. / [VY1 ***]
Set VOL YNOFS3 to the current setting value plus 4. / [VY3 ***]
Set VOL YNOFS4 to the current setting value plus 4. / [VY4 ***]
Current VOL YNOFS3 setting value > 095?
Is there erroneous discharge (abnormal dead cell)?
Display RST MASK 15 (Red 1023+). / [MKS S65]
Is there erroneous discharge (abnormal dead cell)?
Display RST MASK 23 (Magenta 3SF). / [MKS S73]
Set VOL YNOFS3 to the current setting value plus 43. / [VY3 ***]
Set VOL YNOFS4 to the current setting value plus 43. / [VY4 ***]
Is there erroneous discharge (abnormal lit cell)?
(Check on the PANEL 1-ADJ menu.)
B
5
6
Yes
No
Yes
No
Yes
No
Yes
No
PDP-6010FD
6
7
Replacement of abnormal circuits or
re-replacement of the panel required
To the Recovery flowchart (2-2)
From the Recovery flowchart (2-2)
Replacement of abnormal circuits or
re-replacement of the panel required
7
8
A
B
C
D
E
F
135