Indicators On The Hot-Plug Hdd/Ssd Module - Fujitsu PRIMERGY TX2550 M5 Operating Manual

Hide thumbs Also See for PRIMERGY TX2550 M5:
Table of Contents

Advertisement

3.3.2.4

Indicators on the hot-plug HDD/SSD module

Figure 10: Indicators on the hot-plug HDD/SSD module
Pos. Label
1
2
TX2550 M5
Indicator
Status
off
Access
indicator
green on
off
orange
on
Error
indicator
flashing
orange
slowly
Operating Manual
Product description
Description
The HDD/SSD is inactive.
The HDD/SSD being accessed
No HDD/SSD error detected.
An HDD/SSD error has been
detected.
Possible causes:
– The drive is defective and
needs replacing.
– A RAID rebuild process has
failed.
– The HDD/SSD module has not
been inserted correctly.
HDD/SSD RAID rebuild is in
progress. Data is being restored
after replacing a drive that has
been combined into a RAID array.
35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents