90°
Perforated
angle
Horizontal track
5/16"-18 x 1-1/4"
Hex bolt
3/4" To 7/8"
Horizontal tracks
23
Attaching Weather Seal
Permanently attach the weatherstrips on both door jambs and header. The weatherstrips
were temporarily attached in Preparing the Opening, in the pre-installation section of this
manual.
NOTE: When permanently attaching the weatherstrips to the jambs, avoid pushing the weath-
erstrips too tightly against the face of door.
(3) 5/16"
(3) 5/16" Bolts and
Bolts and nuts
(3) 5/16" nuts
Perforated angle bolted
using (2) 5/16" x 1-5/8"
hex head lag screws to
ceiling member and
parallel to door
5/16" Hex nut
NOTE: Repeat the same
process for right hand side.
3/4" To 7/8"
Door edges
NOTE: Door not shown for clarity.
Header
Jamb
Weather
Jamb
seal
24
Balancing Door
Remove locking pliers. Lift door and check its balance. Adjustments to the required number
of spring turns stated may be necessary. If door rises off floor more than 2 ft. under spring
tension alone, reduce spring tension. If the door is hard to rise or drifts down on its own, add
spring tension. A poorly balanced door can cause garage door operator problems.
To adjust spring tension, fully close door. Apply locking pliers to track above third track roller.
Place locking pliers on torsion shaft, as shown in Step Attaching Counterbalance Lift Cables.
Insert a winding rod into the winding cone. Push upward on the winding rod slightly while
carefully loosening the set screws in the winding cone.
IMPORTANT: BE PREPARED TO SUPPORT THE FULL FORCE OF THE TORSION SPRING ONCE
THE SET SCREWS ARE LOOSE.
Carefully adjust spring tension 1/4 turn. Retighten both set screws to 14-15 ft. lbs. of torque
in the winding cone and repeat for the other side. Recheck door balance and re-adjust spring
tension if needed.
IMPORTANT: DO NOT ADJUST MORE THAN 1 TURN FROM THE RECOMMENDED NUMBER
OF TURNS.
If the door still does not operate easily, lower the door into the closed position, unwind
spring(s) completely, and recheck the following items:
1.) Is the door level?
2.) Are the torsion shaft and flag angles / angle mount level and plumb?
3.) Does the distance between the flag angles / angle mount equal door width plus 3-3/8" to
3-1/2"?
4.) Do the counterbalance lift cables have equal tension? Adjust if necessary.
5.) Rewind the spring(s).
6.) Make sure door is not rubbing on jambs.
IMPORTANT: IF DOOR STILL DOES NOT BALANCE PROPERLY, THEN CONTACT A TRAINED
DOOR SYSTEM TECHNICIAN.
25
Label Placement
IMPORTANT: USING THE ILLUSTRATION, ATTACH THE APPROPRIATE LABELS TO THE AP-
PROPRIATE LOCATION ON THE SECTION, AS SHOWN.
NOTE: The Spring Warning tag(s) are factory attached (one per spring).
NOTE: Because of different configurations, some labels may require minor relocations.
17
Jamb
Nail
Nail
Weather seal
installed