11. Installation Instruction

11.1 Select the Best Location

11.1.1
Indoor Unit
Do not install the unit in excessive oil fume area
such as kitchen, workshop and etc.
There should not be any heat source or steam
near the unit.
There should not be any obstacles blocking the air
circulation.
A place where air circulation in the room is good.
A place where drainage can be easily done.
A place where noise prevention is taken into
consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the
wall, ceiling, fence or other obstacles.
Recommended installation height for indoor unit
shall be at least 2.5 m.
11.1.2
Outdoor Unit
If an awning is built over the unit to prevent direct
sunlight or rain, be careful that heat radiation from
the condenser is not obstructed.
There should not be any animal or plant which
could be affected by hot air discharged.
Keep the spaces indicated by arrows from wall,
ceiling, fence or other obstacles.
Do not place any obstacles which may cause a
short circuit of the discharged air.
If piping length is over the [piping length for
additional gas], additional refrigerant should be
added as shown in the table.
Table A
Piping size
Capa-
Std.
city
Model
Length
W
(m)
Gas Liquid
(HP)
TE20***
3/4HP 9.52
mm
TE25***
1.0HP
6.35
"
(3/8
)
mm
5
TE35***
1.5HP
"
(1/4
)
12.7
mm
TE42*** 1.75HP
"
(1/2
)
* Table "A" only applicable for single split connection.
* In case of connection to outdoor multi inverter, refer
to installation manual at outdoor unit.
Example: For TE35***
If the unit is installed at 10 m distance, the quantity of
additional refrigerant should be 50 g .... (10-7.5) m x
20 g/m = 50 g.
AMP Air Conditioning
Piping
Addi-
Max
Min.
Max.
Length
tional
Eleva-
Piping
Piping
for
Refri-
tion
Length
Length
add.
gerant
(m)
(m)
(m)
gas
(g/m)
(m)
15
3
15
15
7.5
15
3
15
15
7.5
15
3
15
20
7.5
15
3
15
20
7.5
11.1.3
Indoor/Outdoor Unit Installation
Diagram
P
p i
n i
g
i d
e r
t c
o i
n
(Front side)
Right
Right
Rear
Left
Right
Left
Rear
bottom
Left bottom
50 mm
or more
(Left and right are identical)
Insulation of piping connections
Carry out insulation after
checking for gas leaks and
secure with vinyl tape.
Attaching the remote control holder to the wall
Remote control holder fi xing screws 6
Remote
control 3
Remote control holder 5
Floor
It is advisable to
avoid more than 2
blockage directions.
For better ventilation
& multiple-outdoor
installation, please
consult authorized
dealer/specialist.
This illustration is for explanation purposes only.
The indoor unit will actually face a different way.
36
www.ampair.co.uk | sales@ampair.co.uk
t A
e t
t n
o i
n
n
t o
o t
b
e
n
d
up drain hose
Installation parts you
should purchase ( )
Installation plate 1
Bushing-Sleeve ( )
Sleeve ( )
Putty ( )
(Gum Type Sealer)
Bend the pipe as closely
on the wall as possible,
but be careful that it
doesn't break.
Vinyl tape (wide) ( )
Vinyl tape
• Apply after carrying
out a drainage test.
• To carry out the
drainage test,
remove the air filters
and pour water into
the heat exchanger.
Saddle
(
Power supply cord
Connection cable
Liquid side piping
Gas side piping
Additional drain hose
)
(
)
)
(
(
)
(
)