Timer Control - Panasonic CS-TE20TKEW Service Manual

Hide thumbs Also See for CS-TE20TKEW:
Table of Contents

Advertisement

Reference point
* The horizontal vane angle tolerance is within +/- 5 degree.
12.4.2
Horizontal Airflow
The horizontal airflow direction louver can be adjusted manually by hand.

12.5 Timer Control

There are 2 sets of ON and OFF timer available to turn the unit ON or OFF at different preset time.
If more than one timer had been set, the upcoming timer will be displayed and will activate in sequence.
12.5.1
ON Timer Control
ON timer 1 and ON timer 2 can be set using remote control, the unit with timer set will start operate earlier than
the setting time.
This is to provide a comfortable environment when reaching the set ON time.
60 minutes before the set time, indoor (at fan speed of Lo-) and outdoor fan motor start operate for 30 seconds to
determine the indoor intake air temperature and outdoor air temperature in order to judge the operation starting
time.
From the above judgment, the decided operation will start operate earlier than the set time as shown below.
Indoor intake air
o
temperature (
C)
30
25
5 min
Cooling/Soft Dry
12.5.2
OFF Timer Control
OFF timer 1 and OFF timer 2 can be set using remote control, the unit with timer set will stop operate at set time.
AMP Air Conditioning
Side View (Outer Vane)
Closed
Stopper
Position
Step 1
Step 2
Step 3
Step 4
15 min
10 min
Outdoor air
o
30
35
(
C)
o
temperature (
C)
Step 5
Figure 2
Indoor intake air
o
temperature (
C)
15
30 min
5
35 min
0
Heating
52
www.ampair.co.uk | sales@ampair.co.uk
135º
25 min
Outdoor air
o
5
(
C)
o
temperature (
C)