Temperature Of Damper - Check - Mitsubishi S6B3 Operation & Maintenance Manual

Table of Contents

Advertisement

Chapter 3 OPERATION

Temperature of Damper - Check

Damper temperature management by
thermo label
It is recommended to use the thermo label for temper-
ature management of the damper. Check the thermo
label before starting engine.
1. Check the thermal part of thermo label is black.
2. Note the highest temperature of thermal part. Note
the temperature periodically, and check the abnor-
mality of temperature alteration.
If the abnormality of temperature alteration is found,
consult a dealer of Mitsubishi Heavy Industries, Ltd.
Note: For damper temperature limit and inspection, re-
fer to
"Damper - Inspect"
3-12
(8-4).
(Display example)
When thermal part of the thermo label is
black until 80, it indicates that the
maximum temperature of damper during
operating is from 80°C [176°F] to
85°C [185°F].
Fig. 3-17 Thermo label of damper
Thermo label
5E-100
100 105 110 115 120
5E-75
75
80
85
90
95
5E-50
50
55
60
65
70

Hide quick links: