Maintenance Of Llc; Replacement Intervals Of Llc; Llc Concentration; Table 6-3 Recommended Llc Concentration - Mitsubishi S6B3 Operation & Maintenance Manual

Table of Contents

Advertisement

Chapter 6 COOLANT

Maintenance of LLC

Should coolant or LLC be accidentally swallowed, induce vomiting immediately and seek medical attention. If LLC
should enter eyes, flush immediately with plenty of water and seek medical attention.
LLC is toxic. Never dispose of coolant containing LLC drained from engine into regular sewage. For disposal of
used coolant, consult LLC distributor.

Replacement Intervals of LLC

Be sure to renew LLC (coolant) at the intervals specified in this manual.
Failure to renew LLC may cause malfunctions due to performance degradation of preventing rust and cavitation.
When a coolant mixed with the LLC recommended by our company is used, replace coolant every 8000 hours or 2
years, whichever comes first.

LLC Concentration

Keep the LLC concentration of 30 % (GLASSY) and 40 % (PG GLASSY) on any temperature conditions. LLC of
less than 30 % concentration does not provide sufficient corrosion protection. If the LLC concentration is lower than
10 %, it may accelerate corrosion.
When adding coolant, do not add plain water. Always use coolant with the same LLC concentration.
Item
GLASSY
LLC concentration
(%)
PG GLASSY
Note: (a) If the outside air temperature is -30°C [-22°F] or lower, use "GLASSY."
(b) The concentration above is based on Mitsubishi Heavy Industries, Ltd. genuine LLC "GLASSY long life
coolant (Ethylene glycol type)" or "PG GLASSY long life coolant (Non-amine type)."
For determining the accurate LLC concentration, refer to the instructions for the LLC used.
6-6

Table 6-3 Recommended LLC Concentration

Appear-
Type
-10°C [14°F]
ance
Green
Red
Lowest ambient temperature
-20°C [-4°F]
or above
or above
30
40
40
55
-30°C [-22°F]
-45°C [-49°F]
or above
or above
50
60
70
-