Wiring For Bridge-Mono 70 Volt Mode (140 Volt Output) - Crown Com-Tech CT-210 Reference Manual

Crown com-tech ct-210: reference guide
Hide thumbs Also See for Com-Tech CT-210:
Table of Contents

Advertisement

Com-Tech Power Amplifiers
WARNING: Both channels must be configured for
the same output mode (8/4-ohm or 70-volt) before
switching to Bridge-Mono mode.
Bridge-Mono wiring is very different from the other
modes and requires special attention. First, turn the
amplifier off. Then select Bridge-Mono mode by sliding
the dual/mono switch to the BRIDGE MONO (right) po-
sition. Both outputs will receive the signal from Channel
1 with the output of Channel 2 inverted so it can be
bridged with the Channel 1 output. DO NOT USE THE
CHANNEL 2 INPUT or the signal level and quality may
be greatly degraded. Also, keep the Channel 2 Input
Attenuation control turned down completely (counter-
clockwise).
Note: The Channel 2 input jack and Input Attenuation
control are not defeated in Bridge-Mono mode. A signal
feeding Channel 2 will work against the Channel 1 sig-
nal, and usually results in distortion and inefficient op-
eration.
Connect the load across the two positive (+) output ter-
minals (see Figure 3.6 and the middle illustration in Fig-
ure 3.7). The positive lead from the load connects to the
positive Channel 1 terminal, and the negative (or
ground) lead from the load connects to the positive
MIXER
Com-Tech Amplifier
BRIDGE-MONO
70 VOLT MODE
(140 VOLT OUTPUT)
Reference Manual
CHANNEL 1
DO NOT
USE
BB
REMOTE
CH2
PUSH TO RESET
+
+
Programmable
Input Processor (P.I.P.)
11
10
9
8
13
7
15
6
17
5
19
4
21
3
25
2
32
1
.5
dB
0
CH-2
TURN OFF CHANNEL 2 (CCW)
IN BRIDGE-MONO MODE.
DUAL
TURN OFF THE AMPLIFIER
PARALLEL
BRIDGE
BEFORE CHANGING
MONO
MONO
THE DUAL/MONO SWITCH.
Fig. 3.6 Wiring for Bridge-Mono 70-Volt Mode (140-Volt Output)
Channel 2 terminal. Do not connect the output
grounds ( ). Also, the load must be balanced (neither
side shorted to ground).
CAUTION: Connect only balanced equipment
(meters, switches, etc.) to the Bridge-Mono output.
Both sides of the line must be isolated from the in-
put grounds or oscillations may occur.
PARALLEL
MONO
P A R A L L E L - M O N O
Parallel-Mono mode is used to drive loads with a total
impedance of less than 4 ohms when using 8/4-ohm
output mode (see Bridge-Mono if the load is greater
than 4 ohms). This mode can also be used to drive a
single high-powered 70-volt constant voltage line.
Parallel-Mono installation is very different from the other
modes and requires special attention.
WARNING: Both channels must be configured for
the same output mode (8/4-ohm or 70-volt) before
switching to Parallel-Mono mode.
8/4
70
8/4
70
OHM
VOLT
OHM
VOLT
CH1
CH2
CH1
11
10
9
8
13
7
15
6
17
5
19
4
21
3
25
2
32
1
.5
dB
0
CH-1
140 VOLT LINE
DO NOT USE
THE GROUND
TERMINALS
DUAL
BRIDGE
MONO
TURN OFF THE AMPLIFIER
BEFORE CHANGING THE
OUTPUT MODE SWITCHES.
WARNING: BOTH CHAN-
NELS MUST BE SET TO
70 VOLT MODE.
+
+
16, 8, OR 4 OHM
COM
140 VOLT STEP-DOWN
LOUDSPEAKERS
TRANSFORMERS
+
+
16, 8, OR 4 OHM
COM