Com-Tech Power Amplifiers
In an effort to provide you with as much information as possible about the high power-producing capabilities of your amplifier, we
have created the following power matrices.
Minimum Guaranteed Power Specifications
Crown's minimum power specifications represent the absolute smallest amount of output power you can expect from your amplifier
when it is driven to full output under the given conditions. Some spaces in each matrix may be left blank because the same guarantee
is not provided for those conditions—however, your amplifier will perform well under all conditions listed in each matrix.
When measuring power, 0.1% THD appears to be the industry standard for distortion. Two of the maximum average power specifica-
tions shown in each minimum power matrix are measured at 0.1% THD so you can easily compare Crown specifications to those of
other manufacturers. But this high level of distortion actually allows for some clipping which is undesirable. Because of this, a maxi-
mum average power specification at 0.05% THD is included in each minimum power matrix which represents non-clipped conditions.
Although most manufacturers do not give you power specifications at 0.05% THD, we encourage them to provide these specifica-
tions so you will have a more realistic representation of the way amplifiers should be used in the real world—without a clipped output
signal.
Many manufacturers publish power specs with a tolerance of ±1 dB or worse. This means their amplifier can deviate more than 20%
in output! A 100 watt amplifier would meet their specification if it only produced 79.4 watts. Other manufacturers qualify their specs by
Com-Tech 210 – Minimum Guaranteed Power (Watts)
Dual/Mono
At 0.1% THD
Mode
4
Dual
8
(both channels
driven)
50 (70V)
8
Bridge-Mono
16
(balanced output)
100 (140V)
2
Parallel-Mono
4
25 (70V)
4
Dual
8
(both channels
driven)
50 (70V)
8
Bridge-Mono
16
(balanced output)
100 (140V)
2
Parallel-Mono
4
25 (70V)
4
Dual
8
(both channels
driven)
50 (70V)
8
Bridge-Mono
16
(balanced output)
100 (140V)
2
Parallel-Mono
4
25 (70V)
Fig. 6.1 Com-Tech 210 Minimum Power Matrix
Reference Manual
Crown specifications are guaranteed for three years.
Maximum Average
At 0.1% THD
At 0.05% THD
(See note 1)
(See note 2)
(See note 3)
1 kHz
20Hz-20kHz
1 kHz
150
135
145
110
105
105
110
105
110
300
270
295
220
210
215
205
200
205
295
290
215
210
210
205
145
135
145
110
105
110
105
95
105
290
265
285
220
210
220
205
195
205
290
285
215
210
210
205
150
140
150
115
110
115
105
100
105
300
275
295
230
220
225
215
200
210
300
300
225
225
215
215
saying they are "typical, " "subject to manufac-
turing tolerances, " "single channel driven" or
that they are specified with "fuses bypassed. "
FTC Continuous Average
Each of these statements effectively removes
At 0.1% THD
any performance guarantee. In fact, some
(See note 4)
manufacturers use these tactics to generate
large power numbers, and they don't even print
1 kHz
20Hz-20kHz
a disclaimer. We take a different approach at
140
125
Crown—our amplifiers are guaranteed to meet
105
100
or exceed their specifications for three years.
Further, because our published specs are set
110
105
below our "in-house" measurements, you can
270
250
expect every Crown amplifier to exceed its pub-
210
205
lished minimum power specs. We believe you
should get what you pay for.
205
200
275
Minimum Power Notes:
All minimum power specifications are based on
215
0.5% regulated AC mains with THD of less than
205
1.0% and an ambient room temperature of 70° F
135
125
(21° C). Standard EIA power (RS-490) is not shown
here because it is identical to FTC Continuous Av-
110
105
erage Power.
100
95
1. A 1 kHz sine wave is presented to the amplifier
275
250
and the output monitored for nonlinear distor-
tion. The level is increased until THD reaches
215
205
0.1%. At this point, average power per channel
205
190
is reported.
270
2. A sine wave is presented to the amplifier over
210
the range from 20 Hz to 20 kHz and the output
monitored for nonlinear distortion. The level at
205
each frequency is increased until THD reaches
140
130
0.1%. At this point, average power per channel
is reported.
110
105
3. A 1 kHz sine wave is presented to the amplifier
105
95
and the output monitored for nonlinear distor-
280
260
tion. The level is increased until THD reaches
225
215
0.05%. At this point, average power per chan-
nel is reported.
210
195
4. Continuous power in the context of Federal
275
Trade Commission testing is understood to be
220
a minimum of five minutes of operation. Har-
monic distortion is measured as the RMS sum
210
total and given as a percentage of the funda-
mental output voltage. This applies for all watt-
ages greater than 0.25 watts.