Wiring Connections; Main Harness (H1), 12-Pin Connector; H2 Harness, 18-Pin Connector; Remote Start, (H3) 10-Pin Connector - Directed Electronics Viper 5902 Installation Manual

Responder hd models
Table of Contents

Advertisement

To change

Wiring Connections

jumper settings
TACH threshold OFF:

Main Harness (H1), 12-pin connector

TACH threshold ON:
RED/WHITE
H1/1
H1/2
RED
IMPORTANT! Neutral Safety
switch must be plugged in
H1/3
BROWN
and in the ON position
H1/4
WHITE/BROWN
H1/5
BLACK
H1/6
VIOLET
H1/7
BLUE
H1/8
GREEN
H1/9
BLACK/WHITE
H1/10
WHITE/BLUE
H1/11
WHITE
ORANGE
H1/12
*The Normally Closed setting will only work if one of the vehicle's doors is connected. If more than one door
is to be monitored, then it is recommended to use the Xpresskit DTIMAZDA or tech tip # 1921 on www.direct-
echs.com to interface with these types of vehicles.

H2 Harness, 18-pin connector

LIGHT GREEN/BLACK
H2/1
H2/2
ORANGE/BLACK
H2/3
GREEN/WHITE
H2/4
VIOLET/BLACK
H2/5
WHITE/BLACK
H2/6
WHITE/VIOLET
H2/7
GREY/BLACK
H2/8
BROWN/BLACK
H2/9
VIOLET/WHITE
TACH threshold OFF:
H2/10
DARK BLUE
TACH threshold ON:
H2/11
PINK/WHITE
H2/12
ORANGE
H2/13
PURPLE
Bitwriter
Port
H2/14
PINK
H2/15
GREY
H2/16
BLUE/WHITE
H2/17
BROWN
H2/18
BLACK/WHITE

Remote Start, (H3) 10-pin connector

H3/1
PINK
H3/2
RED/WHITE
H3/3
ORANGE
H3/4
VIOLET
6
(for external
10A FUSE
MINI ATM
Xpresskit
Bitwriter
RPN: 8540
interface
Port
module)
(-) 200mA AUX/TRUNK OUTPUT
(+)12VDC CONSTANT INPUT
(+) SIREN OUTPUT
ON
PARKING LIGHT ISOLATION WIRE - PIN 87a of onboard relay
(-) CHASSIS GROUND
(+) DOOR TRIGGER INPUT
(-) TRUNK PIN/ INSTANT TRIGGER INPUT (N/C OR N/O)
(-) DOOR TRIGGER INPUT (N/C* OR N/O)
(-) 200mA DOME LIGHT SUPERVISION OUTPUT
(-) REMOTE START/ TURBO TIMER ACTIVATION INPUT
1
PARKING LIGHT OUTPUT
1
(-) 500mA GROUND WHEN ARMED OUTPUT
1
1
5
1
3
18
9
(-) 200mA OEM ALARM DISARM OUTPUT
(-) 200mA AUX 4 OUTPUT
(-) 200mA OEM ALARM ARM OUTPUT
(-) 200mA AUX 2 OUTPUT
(-) 200mA AUX 3 OUTPUT
(-) 200mA AUX 1 OUTPUT
(-) DIESEL WAIT TO START INPUT
(-) 200mA HORN HONK OUTPUT
TACHOMETER INPUT
To change
(-) 200mA STATUS OUTPUT
jumper
settings
(-) 200mA FLEX RELAY CONTROL OUTPUT
(-) 200mA ACCESSORY OUTPUT
(-) 200mA STARTER OUTPUT
Neutral Safety
Remote
Switch
Start In
(-) 200mA IGNITION 1 OUTPUT
(-) HOOD PIN INPUT (N/C OR N/O)
(-) 200mA 2ND STATUS /REAR DEFOGGER OUTPUT
(+) BRAKE SHUTDOWN INPUT
(-) NEUTRAL SAFETY INPUT
1
12
1
10
(+) IGNITION 1 INPUT/OUTPUT
1
8
(87) FLEX RELAY +12V INPUT (30A FUSED)
(+) ACCESSORY OUTPUT
1
5
(+) STARTER OUTPUT (CAR SIDE OF THE STARTER KILL)
1
3
Neutral Safety
Remote
Door Lock/
Switch
Start In
Unlock Output
10
1
12
5
1
10
Bitwriter
Port
1
8
Neutral Safety
Switch
1
5
1
3
10
9
8
7
12
5
4
3
2
10
8
1
10
1
CPU1
Door Lock/
H2
Relay Out
Unlock Output
Port
Port
10
9
8
7
6
5
4
3
2
1
1
12
H2
Relay Out
Port
Port
CPU1
9
8
7
6
4
3
2
1
Valet
Status
Port
LED
1
12
6
1
12
NOTE: Pin 1 is on the left
Valet
Status
Port
LED
© 2009 Directed Electronics. All rights reserved.
Valet
Status
Port
LED
Optional Mux P
(for additional sen
ELECTRONICS
R
4
3
ELECTRONICS
2
1
TACH LEARN THREASHOLD
JMP1 OFF
ON

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clifford 590.2xPython 592