General Information - Napoleon Ultra chef UD405RSB User Manual

Hide thumbs Also See for Ultra chef UD405RSB:
Table of Contents

Advertisement

Available languages

Available languages

4

General Information

This Gas Barbecue Is Certified Under Canadian And American National Standards, CAN/CGA-1.6b-2002 and
ANSI Z21.58b-2002 respectively for Outdoor Gas Grills and should be installed to conform with local codes. In
absence of local codes, install to the current CAN/CSA-B149.1 Propane Installation Code in Canada or to the
National Fuel Gas Code, ANSIZ223.1/NFPA 54 in the United States.
If a rotisserie motor is used, it must be electrically grounded in accordance with local codes or, in absence of
local codes, with the current CSA C22.1Canadian Electrical Code in Canada or the National Electrical Code,
ANSI/NFPA 70 in the United States.
California proposition 65: The burning of gas fuel creates by-products, some of which are on the list as
substances known by the State of California to cause cancer or reproductive harm. When cooking with gas,
always ensure adequate ventilation to the unit, to minimize exposure to such substances.
Propane Cylinder Specifications
WARNING!
occur.
A dented or rusty cylinder may be hazardous and should be checked by your propane supplier. Never use a
cylinder with a damaged valve. Use only a propane supply cylinder constructed and marked in accordance
with the specifications for LP-gas cylinders of the National Standard of Canada, CAN/CSA-b339, Cylinders,
Spheres and Tubes for Transportation of Dangerous Goods; and Commission, as applicable or the Specifications
for LP-Gas Cylinders of the U.S. Department of Transportation (D.O.T.). This appliance has been designed for
use with a 20 lb. (9.1 kg) size propane cylinder only (not supplied).
The propane cylinder must be provided with a cylinder connection device compatible with the connection
for outdoor cooking appliances. The propane cylinder must be provided with a shut-off valve terminating in
a propane cylinder valve type QCC1, and a safety relief device having direct communication with the vapor
space of the cylinder. The cylinder supply system must be arranged for vapor withdrawal and the cylinder
shall include a collar to protect the cylinder valve. The cylinder shall incorporate a listed OPD (overfill protection
device). Do not store a spare LP-gas cylinder under or near this appliance. Never fill the cylinder beyond 80
percent full.
Use only the pressure regulator and hose assembly provided with this barbecue. Replacement pressure
regulators and hose assemblies must be specified by the manufacturer. Do not store a spare propane cylinder
on the shelf beneath the barbecue.
The regulator supplies a pressure of 11 inches. water column to the gas grill and has a QCC1 type fitting.
Cylinders to be used with this unit must be supplied with a QCC1 cylinder valve. A QCC1 cylinder has a
positive seating connection, which will not allow gas flow until a positive seal has been achieved. It is also
equipped with an excess flow device. In order to attain full flow to the grill, the valves must be in the off position
when the cylinder valve is turned on.
Gas Hook-Up Instructions
WARNING!
pan.
Propane Cylinder Installation: Set cylinder into hole in bottom shelf.
Cylinder Connection: Ensure the gas regulator hose is kink free. Remove the cap or plug from the cylinder fuel
valve. Insert the black QCC1 regulator nipple onto the QCC1 fuel valve. Hand tighten clockwise. Do not use
tools. Leak test all joints prior to using the grill. A leak test must be performed annually and each time a cylinder
is hooked up or if a part of the gas system is replaced.
If this grill is to be connected directly to a house propane gas supply line, follow the instructions for the natural
gas hook-up. Optional side burners must also follow the natural gas hook-up instructions. Note: The propane
tank heat shield is not required when the grill is connected to a fixed fuel supply, as its sole function is to shield
the propane tank normally used with the grill. Ensure that the supply pressure is 11 inches water column.
Natural Gas Hook-Up: These connections must be made by a licensed gas fitter. This natural gas grill is supplied
with a gas supply hose (complete with a quick disconnect) designed for natural gas and certified for outdoor
use. The gas grill is designed to operate at an inlet pressure of 7 inches water column. Piping and valves
upstream of the quick disconnect are not supplied. The installation must comply with CAN B149.1 Natural Gas
and Propane installation code in Canada, or to the National Fuel Gas Code, ANSI Z223.1 in the United States.
www.ultrachefgrills.com
If these instructions are not followed exactly, a fire causing death or serious injury may
A fire will result if the gas supply hose makes contact with the underside of the grill or drip

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents