Table 3 – Equipment Configuration Outputs
For COOL, HEAT and Emergency Heat modes, the following chart shows the
state for each output in each stage of operation
EQUIP
HARD-
CONFIG
WARE
OPTION 01
CONFIG
SS AC
AC
HP
SS AC
2S
SS HP
HP
RVS + O
SS HP
HP
RVS + B
SS HP
RVS + O
2S
Opt43 = On
SS HP
RVS + B
2S
Opt43 = On
2SPD AC
2S
2SPD HP
2S
RVS + O
COOL
COOL
HEAT
STG 1
STG 2
STG 1
Y/Y2
-
W/W1
Y/Y2
-
W/W1
Y/Y2,
-
Y/Y2
O/W2/B
Y/Y2,
Y/Y2
-
O/W2/B
Y/Y2,
-
Y/Y2
O/W2/B
Y/Y2,
Y/Y2
-
O/W2/B
Y/Y2,
Y1/W2
W/W1
Y1W2
Y1/W2
Y1/W2
Y/Y2
Y1/W2
O/W2/B
O/W2/B
HEAT
HEAT
STG 2
STG 3
-
-
W/W1
O/W2/B
-
(if
Opt32+2)
Y/Y2,
-
W/W1
Y/Y2,
W/W1,
-
O/W2/B
Y/Y2,
Y/Y2
W/W1
Y1/W2
Y/Y2,
Y/Y2,
W/W1,
Y1/W2,
O/W2/B
O/W2/B
W/W1
-
O/W2/B
Y1/W2
Y1/W2
Y/Y2
Y/Y2
W/W1
47
EM
EM
HEAT
HEAT
HEAT
STG 4
STG 1
STG 2
-
-
-
-
-
-
-
W/W1
-
-
W/W1
-
Y/Y2
W/W1
W/W1
W/W1
Y1/W2
Y1/W2
Y/Y2,
Y1/W2,
W/W1
W/W1
W/W1
Y1/W2
O/W2/B
-
-
-
-
W/W1
-