Vent Clearance - Rinnai RHE1S40N Installation And Operation Manual

High-efficiency (he) series infrared gas heater
Table of Contents

Advertisement

WARNING
to the IR heating system thermostat or in the absence of such thermostat, in a conspicuous
place specifying the required clearances from the heater to the combustibles.
Use a permanent marker to record the required clearance dimensions on the sign.
'H' is a value calculated at site: (H = T - C) Refer to Figure 1 and Table 1 above
Measure the on site distance between bottom of the heater and the floor = 'T' inches (cm).
The minimum clearance to combustibles below this heater 'C' is 53 inches (1346 cm)
Subtract 'C' 53 inches (1346 mm) from
'T' (Height above floor) to get value 'H'.
Enter the calculated value 'H' on the sign
Enter the values as required for the other dimen-
sions:
'S' = 24" (610 mm)
'F'= 48" (1120 mm)
'B' = 12" (305 mm) at 30°
Or 'B' = 24" if mount angle less than 30°
POST THIS SIGN ADJACENT TO THE HEATER
THERMOSTAT OR IN A PROMINENT LOCATION.
VENT CLEARANCE: Clearance from single wall 'C' vent pipe inside the building is deter-
mined by local or national installation codes, but must not be less than 6 inches (150 mm).
Clearance from the vent terminal outside the structure are indicated in Section 11 Flue Vent-
ing and Figures 9 to 12, pages 19 to 23 for details and requirements for venting.
HE Series Infrared Gas Heater Installation and Operation Manual
For your convenience a "peel and stick" sign is provided
with this heater. This sign must be posted either adjacent
10
24"
48"
12"