Download Print this page

Squelch Tight Adjustment (Wide Bandwidth); Squelch Tight Adjustment (Narrow Bandwidth) - Vertex Standard HX400 Alignment Manual

Advertisement

  Change the RF Signal Generator to 174.000 MHz. The output level keeps –8 dBμV (with a 
standard FM modulation: ±1.5 kHz deviation @ 1 kHz). 
  Press the [H/L] key to read the Squelch Threshold level, then press and hold the [H/L] key 
for 2 seconds to save the Squelch Threshold level at the high band edge. 
  Press the [ ] key twice to change the "H" character to "L" at the lower right corner of the 
display. 
  Change the RF Signal Generator to 134.000 MHz. The output level keeps –8 dBμV (with a 
standard FM modulation: ±1.5 kHz deviation @ 1 kHz). 
  Press  and  hold  the  [H/L] key for 2  seconds  to  read the  Squelch Threshold  level  at  the low 
band edge. 
  Press the [CLR] key to exit from this alignment item. 
 
Squelch Tight Adjustment (Wide Bandwidth) 
Press the [ ] or [ ] key to select the display to "N TI W". 
  Press the [SQL] key to enable adjustment of the Squelch Tight level. 
  Press the [ ] or [ ] key to select a small character of lower right corner of the display to 
"C". 
  Set the RF Signal Generator output level 0 dBμV (with a standard FM modulation: ±3.0 kHz 
deviation @ 1 kHz) at 156.800 MHz 
  Press the [H/L] key to read the Squelch Tight level, then press and hold the [H/L] key for 2 
seconds to save the Squelch Tight level at the band center. 
  Press  the  [ ]  key  to  change  the  "C"  character  to  "H"  at  the  lower  right  corner  of  the 
display. 
  Change  the  RF  Signal  Generator  to  174.000  MHz.  The  output  level  keeps  0  dBμV  (with  a 
standard FM modulation: ±3.0 kHz deviation @ 1 kHz). 
  Press the [H/L] key to read the Squelch Tight level, then press and hold the [H/L] key for 2 
seconds to save the Squelch Tight level at the high band edge. 
  Press the [ ] key twice to change the "H" character to "L" at the lower right corner of the 
display. 
  Change  the  RF  Signal  Generator  to  134.000  MHz.  The  output  level  keeps  0  dBμV  (with  a 
standard FM modulation: ±3.0 kHz deviation @ 1 kHz). 
  Press the [H/L] key to read the Squelch Tight level, then press and hold the [H/L] key for 2 
seconds to save the Squelch Tight level at the low band edge. 
  Press the [CLR] key to exit from this alignment item. 
 
Squelch Tight Adjustment (Narrow Bandwidth) 
  Press the [ ] or [ ] key to select the display to "N TI N". 
  Press the [SQL] key to enable adjustment of the Squelch Tight level. 
  Press the [ ] or [ ] key to select a small character of lower right corner of the display to 
"C". 
  Set the RF Signal Generator output level 0 dBμV (with a standard FM modulation: ±1.5 kHz 
deviation @ 1 kHz) at 156.800 MHz 
  Press the [H/L] key to read the Squelch Tight level, then press and hold the [H/L] key for 2 
seconds to save the Squelch Tight level at the band center. 
  Press  the  [ ]  key  to  change  the  "C"  character  to  "H"  at  the  lower  right  corner  of  the 
display. 
  Change  the  RF  Signal  Generator  to  174.000  MHz.  The  output  level  keeps  0  dBμV  (with  a 
standard FM modulation: ±1.5 kHz deviation @ 1 kHz). 
4