Advertisement

Hardware Guide
OmniSwitch 2220
OmniSwitch 2220 Hardware Guide
060524-10 Rev. A
Alcatel-Lucent Enterprise
April 2018

Advertisement

Table of Contents
loading

Summary of Contents for Alcatel-Lucent OmniSwitch 2220

  • Page 1 Hardware Guide OmniSwitch 2220 OmniSwitch 2220 Hardware Guide 060524-10 Rev. A Alcatel-Lucent Enterprise April 2018...
  • Page 2 Alcatel-Lucent and the Alcatel-Lucent Enterprise logo are trademarks of Alcatel- Lucent. To view other trademarks used by affiliated companies of ALE Holding, visit: enterprise.alcatel- lucent.com/trademarks. All other trademarks are the property of their respective owners. The information presented is subject to change without notice. Neither ALE Holding nor any of its affiliates assumes any responsibility for inaccuracies contained herein.
  • Page 3: Important Documents

    General Information S e c t i o n 1 : G e n e r a l I n f o r m a t i o n This document contains hardware information for the OmniSwitch 2220. Important Documents Note: Access to technical documentation and software is available from the Service &...
  • Page 4 OmniSwitch 2220 Hardware Guide OmniSwitch 2220 Hardware Information S e c t i o n 2 : O m n i S w i t c h 2 2 2 0 H a r d w a r e I n f o r m a t i o n...
  • Page 5 OmniSwitch 2220 Hardware Guide OmniSwitch 2220 Chassis Specifications OmniSwitch 2220 Chassis Specifications OS2220-8 Figure 1: OS2220-8 Front/Rear Item Description Port / System Status LEDs / Reset Button (8) 10/100/1000 RJ-45 Ports (2) SFP Ports AC Power Input Alcatel-Lucent Enterprise OmniSwitch 2220 Hardware Guide April 2018 •...
  • Page 6 OmniSwitch 2220 Hardware Guide OmniSwitch 2220 Chassis Specifications OS2220-P8 Figure 2: OS2220-P8 Front/Rear Item Description Port / System Status LEDs / Reset Button (8) 10/100/1000 RJ-45 802.3at PoE Ports (2) SFP Ports AC Power Input Alcatel-Lucent Enterprise OmniSwitch 2220 Hardware Guide April 2018 •...
  • Page 7 OmniSwitch 2220 Hardware Guide OmniSwitch 2220 Chassis Specifications OS2220-24 Figure 3: OS2220-24 Front/Rear Item Description Port / System Status LEDs / Reset Button (24) 10/100/1000 RJ-45 Ports (2) SFP Ports AC Power Input Alcatel-Lucent Enterprise OmniSwitch 2220 Hardware Guide April 2018 • 060524-10 Rev. A...
  • Page 8 OmniSwitch 2220 Hardware Guide OmniSwitch 2220 Chassis Specifications OS2220-P24 Figure 4: OS2220-P24 Front/Rear Item Description Port / System Status LEDs / Reset Button (24) 10/100/1000 RJ-45 802.3at PoE Ports (2) SFP Ports AC Power Input Fans Alcatel-Lucent Enterprise OmniSwitch 2220 Hardware Guide April 2018 •...
  • Page 9: Chassis Specifications

    OmniSwitch 2220 Hardware Guide OmniSwitch 2220 Chassis Specifications Chassis Specifications Table 1: Hardware Specifications OS2220-8 OS2220-P8 OS2220-24 OS2220-P24 RJ-45 10/100/ 1000 portsll 1G Combo/SFP uplink ports PoE ports 802.3at ports Width 33 cm 33 cm 44.0 cm 44.0 cm (12.99 in) (12.99 in)
  • Page 10: Rack Mounting

    OmniSwitch 2220 Hardware Guide OmniSwitch 2220 Chassis Specifications Rack Mounting 1. Attach rack mount brackets to both sides of the chassis as shown. The OS2220-8/P8 models user longer brackets to fit in a 19” rack. 2. Lift and position the switch until the rack-mount brackets are flush with the rack post, then align the holes in the brackets and insert and secure all rack-mount screws.
  • Page 11: Power Connections

    OmniSwitch 2220 Hardware Guide OmniSwitch 2220 Chassis Specifications Power Connections 1. Plug the provided power cord into the power supply’s socket on rear of chassis as shown. Figure 6: Power Connection Transceivers Transceivers Description SFP-GIG-T 1000Base-T Gigabit Ethernet Transceiver SFP...
  • Page 12: Regulatory Compliance And Safety Information

    OmniSwitch 2220 Hardware Guide Regulatory Compliance and Safety Information S e c t i o n 3 : R e g u l a t o r y C o m p l i a n c e a n d...
  • Page 13: China Rohs: Hazardous Substance Table

    OmniSwitch 2220 Hardware Guide Regulatory Compliance and Safety Information China RoHS: Hazardous Substance Table Alcatel-Lucent Enterprise OmniSwitch 2220 Hardware Guide April 2018 • 060524-10 Rev. A Page 13...
  • Page 14: California Proposition 65 Warning

    OmniSwitch 2220 Hardware Guide Regulatory Compliance and Safety Information Taiwan RoHS: Hazardous Substance Table California Proposition 65 Warning WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Products are packaged using one or more of the following packaging materials:...
  • Page 15: Standards Compliance

    OmniSwitch 2220 Hardware Guide Regulatory Compliance and Safety Information Standards Compliance The product bears the CE mark. In addition it is in compliance with the following other safety and EMC standards. Note: All hardware switching modules used in an OmniSwitch switch comply with Class A standards. Modules with copper connectors meet Class A requirements using unshielded (UTP) cables.
  • Page 16: Fcc Class A, Part

    OmniSwitch 2220 Hardware Guide Regulatory Compliance and Safety Information • EN 61000-4-3 • EN 61000-4-4 • EN 61000-4-5 • EN 61000-4-6 • EN 61000-4-8 • EN 61000-4-11 • IEEE 802.3: Hi-Pot Test • (2250 V DC on all Ethernet ports) Environmental Standards •...
  • Page 17: Canada Class A Statement

    OmniSwitch 2220 Hardware Guide Regulatory Compliance and Safety Information If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. Canada Class A Statement This equipment does not exceed Class A limits per radio noise emissions for digital apparatus, set out in the Radio Interference Regulation of the Canadian Department of Communications.
  • Page 18: Network Cable Installation Warning

    OmniSwitch 2220 Hardware Guide Regulatory Compliance and Safety Information Class A Warning for Taiwan and Other Chinese Markets This is a Class A Information Product. When used in a residential environment, it may cause radio frequency interference. Under such circumstances, the user may be requested to take appropriate countermeasure.
  • Page 19 OmniSwitch 2220 Hardware Guide Regulatory Compliance and Safety Information Español: Las tapaderas blancas regulan la circulación de aire y ayudan a proteger componentes internos del chasis y siempre deben estar instaladas en las ranuras vacías del chasis y fuentes de alimentación.
  • Page 20: Power Disconnection Warning

    OmniSwitch 2220 Hardware Guide Regulatory Compliance and Safety Information Français: Pour réduire tout risque électrique, gardez vos mains et doigts hors des alimentations et ne touchez pas au fond de panier pendant que le commutateur fonctionne. Deutsch: Um die Gefahr des elektrischen Schlages zu verringern, greifen sie bitte nicht in die Spannungsversorgung und berühren sie nicht die Rückwandplatine während das Gerät arbeitet.
  • Page 21: Dc Power Supply Connection Warning

    OmniSwitch 2220 Hardware Guide Regulatory Compliance and Safety Information • Cualquier otro equipo a cual se conecte este producto también debe estar conectado a tomas de alimentación adecuadamente cableadas. DC Power Supply Connection Warning For EMC/EMI, each DC/DC power supply requires that the ground wire is connected from each DC/DC power supply to Common Earth Ground.
  • Page 22: Instrucciones De Seguridad En Español

    OmniSwitch 2220 Hardware Guide Regulatory Compliance and Safety Information Wrist Strap Warning Because electrostatic discharge (ESD) can damage switch components, you must follow proper procedures to eliminate ESD from your person and the surrounding area before handling switch components. Français: Parce que les décharges électrostatiques (ESD) peuvent endommager les composants de commutation, vous devez suivre les procédures appropriées pour éliminer ESD de votre personne et la région...
  • Page 23: Advertencia De Acceso Restringido

    Deseche las baterías usadas según las instrucciones del fabricante. Las instrucciones del fabricante son como sigue: Devuelva el módulo con la batería del litio a Alcatel-Lucent. La batería del litio será substituida en la fábrica de Alcatel-Lucent.
  • Page 24: Advertencia De Fuentes De Poder

    OmniSwitch 2220 Hardware Guide Regulatory Compliance and Safety Information Advertencia de fuentes de poder Las unidades OmniSwitch pueden estar equipadas con tres cordones para fuente de poder. Las unidades OmniSwitch 9800 pueden estar equipadas con cuatro cordones para fuente de poder. Para reducir el riesgo de un choque electrico, desconecte todos los cordones de fuente de poder antes de dar servicio a la unidad.

Table of Contents