Part 3
ELECTRICAL CONNECTIONS
3
ELECTRICAL CONNECTION
REQUIREMENTS
This appliance must be installed and grounded on a
branch circuit by a qualified technician in accordance
with the National Electrical code ANSI/NFPA NO. 70 -
latest edition.
All wiring should conform to Local and NEC. This
range requires a single-phase, 3 wire, A.C 120/208V or
120/240V 60Hz electrical system. Use only a 3-conductor
or a 4-conductor UL-listed range cord with closed-
loop terminals, open-end spade lugs with upturned
ends or similar terminations. DO NOT install the
power cord without a strain relief.
A range cord rated at 40 amps with 120/240 minimum
volt range is required. If a 50 amp range cord is used,
it should be marked for use with 1
connection openings.
This appliance may be connected by means of conduit
or power cord. If conduit is being used, go to page 7
3 wire conduit connections or page 8 for 4 wire
conduit connections.
WARNING
• New branch-circuit installations (1996 NEC)
for mobile homes, recreational vehicles,
and installations where local codes do not
allow grounding through the neutral wire
require a 4-conductor UL listed range cord
or 4 wire conduit connection.
Specified power-supply-cord kit rating
Range rating, watts
Specified rating
of power-supply-
120/240 volts
120/208 volts
cord kit, amperes
3-wire
3-wire
8,750 - 16,500
7,801 - 12,500
16,501 - 22,500
12,501 - 18,500
3, 4 - Wire electrical wall Receptacle
4 Wire receptacle (14-50R)
3 Wire receptacle (10-50R)
FIGURE 3
3
" diameter
8
Diameter (inches) of Range
connection Opening
Power cord
40 or 50A
1
/
"
3
8
50
1
/
"
3
8
4

CONNECT RANGE CORD

The Rear Access cover must be removed. Loosen the
three screws with a screwdriver. The terminal block
will then be accessible.
Drawer body cover
(LSE series only)
The Cord/Conduit connection plate is used for the
installation of power cord or conduit. For power cord,
install it with the connection plate as INSTALLED. For
conduit, remove the connection plate located below
the rear of the drawer body and use the conduit hole
(1
/
") instead of power cord hole (1
1
8
(Refer to Figure 5 and 6.)
Tape Measure
Pencil
Remove the Conduit connection plate
Conduit
1
/
"
1
8
1
/
"
1
8
Reinstall the Cord/Conduit connection plate
6
FIGURE 4
Safety Glasses
/
").
3
8
Gloves
FIGURE 5
Assemble the
Rear filler & 2 Screws
strain relief hole
(LSE Series only)