Commissioning
Further information on operation, project planning, programming and diagnosis
of the control system with WIN-PED® 6 is available in the help menus of the
program.
7.2
Commissioning software wIN-PED® 6 and
wIN-PED® 7
For commissioning and for later operation, the user can apply the PC program
WIN-PED®. It can be used for the programming, setting and diagnosis of the
VT-HNC100...3X. Functionality, menus and program windows are adjusted to the
variants of VT-HNC100...3X.
Projects established with WIN-PED® 6 are not compatible with projects from
WIN-PED® 7. Automatic conversion is not possible. However, it is possible to edit
the projects manually.
Ethernet-capable hardware requires WIN-PED® 7. Any other hardware version
operates both with WIN-PED® 6 and WIN-PED® 7.
WIN-PED® offers the following functions:
• Convenient dialog functions for the online or offline settings of the machine data
• NC editor with integrated syntax check and program compiler
• Support for the definition of the parameters used in the NC program
• Dialog window for the online setting of the parameter values
• Various options for the display of the process parameters for digital inputs,
outputs and flags
• Recording and graphic illustrations of up to 16 process parameters with a great
choice of trigger options
• Dialog for the graphic definition of special functions (determination of the
function through a traverse)
• Bus manager for the configuration of data exchange (PROFIBUS DP,
PROFINET RT or CANopen) with superior control
The PC program "WIN-PED" is not included in the scope of delivery of the
VT-HNC100...3X. Download on the Internet:
www.boschrexroth.com/hnc100
7.3

Installation requirements

The following system specifications are required for the PC program WIN-PED®:
• IBM PC or compatible system
• Windows XP or Windows 7 for WIN-PED® 6
• Windows XP or Windows 7 for WIN-PED® 7
• Main memory (recommendation: 512 MB)
• 100 MB available hard drive capacity for each control type
• RS 232 interface for VT-HNC100...3X connection; for the PROFINET RT,
EtherNet/IP or PROFIBUS DP, also the network interface TCP/IP can be used
• An interface cable RS232 (length 3 m; Material no. R900776897) as well
as an USB RS232 converter (Material no. R901066684) are
the scope of delivery, can, however, be ordered separately. See chapter 6.2
"Recommended accessories" on page 21.