Control Cabinet PC
②: The specified 3 A are applied for the operation without further
5 V consumers (e. g. PCI plug-in cards). Limit the operation with fur-
ther 5 V consumers to a total power consumption of 1 A to avoid
that the internal power supply unit switches off accidentally.
If the maximum power consumption has been exceeded, a message
is displayed that the USB devices are disabled. The USB devices op-
erate again as soon as less than 500 mA current is consumed from a
USB socket. Additionally, the USB error message in the taskbar has
to be acknowledged manually.
Connect only USB devices which comply with the noise immunity ac-
cording to the EMC directive (industrial environments). This avoids
an unintended switch-off of the control cabinet PC.

9.5 Ethernet interfaces XETH1 and XETH2

The control cabinet PC can be connected to an Ethernet network via the
Ethernet interfaces XETH1 and EXTH2.
The LAN assignment under Windows to the XLAN connections at the device is
set as follows by default:
Labeling under Windows
Local Area Connection
Local Area Connection 2
RJ45, socket, 8-pin
Type:
Cable length:
Transmission rate:

9.6 DVI interface XDVI

At the DVI connection (XDVI), an external monitor with DVI interface or an ana-
log monitor (via adapter) can be connected.
DVI socket, 24 + 5-pin
Cable length:
Cable type:
Max. resolution:
The resolution and number of the colors are set in the control panel of the ope-
rating system.
DOK-SUPPL*-VPB*40.3***-IT05-EN-P
Labeling at the device
XETH1
XETH2
Ethernet 10 Base-T, 100 Base-T, 1000 Base-T
100 m max.
10, 100 or 1000 MBit/s
1.5 m max.
Shielded, cross-section min. 0.14 mm
2048 × 1536 (QXGA) @ 70 Hz, max. 4294 mill. colors
Bosch Rexroth AG
Interfaces
2
17/57