Download Print this page

Removal Of Outdoor Fan / Fan Motor - Daikin RK20GV1B Service Manual

2.0/2.5/3.0/3.5 kw class

Advertisement

Removal of Outdoor Fan / Fan Motor

2. Removal of Outdoor Fan / Fan Motor
Procedure
Step
1. Remove the outdoor fan.
1
Remove the nut of the
outdoor fan.
2
Remove the outdoor
fan.
2. Remove the fan motor.
1
Disconnect the
connector for the fan
motor [S70].
Release the fan motor
2
lead wire from the
hooks.
Remove the screw and
3
remove the fan motor
fixing frame.
4
Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
D-cut
Outdoor
fan
Nut
Hook
Fan motor lead wire
Fan motor fixing frame
Preparation
Shaft
(R17341)
[S70]
(R17338)
(R17284)
Si00-874
Points
Remove the panels
according to the "Removal
of Outer Panels".
Nut size: M6
10 mm
(R12236)
When reassembling, align
the
mark of the outdoor
fan with the D-cut section of
the motor shaft.
When reassembling, put the
fan motor lead wire through
the back of the fan motor so
as not to be entangled with
the outdoor fan.
Lead wire
Outdoor fan
(R3249)
Removal Procedure

Hide quick links:

Advertisement

loading