Problem
Audible or visual alarm is on. The cabinet has been re-
A
or
shown instead of numbers
on the Temperature Display.
The lamp does not work.
The compressor operates
continually.
Possible cause
There is no voltage in the
mains socket.
cently switched on or the
temperature is too high.
The temperature in the ap-
pliance is too high.
The door is left open.
Temperature sensor prob-
or
symbol is
lem.
The lamp is in stand-by.
The lamp is defective.
Temperature is set incor-
rectly.
Many food products were
put in at the same time.
The room temperature is
too high.
Food products placed in
the appliance were too
warm.
The door is not closed cor-
rectly.
The "Frostmatic" or
"Coolmatic" is switched
on.
The water drainage plug is
not correctly positioned.
Temperature is set incor-
rectly.
Solution
Connect a different electrical
appliance to the mains socket.
Contact a qualified electrician.
Refer to "High temperature
alarm".
Contact a qualified electrician
or contact the nearest Author-
ised Service Centre.
Close the door. Refer to "Door
open alarm"
Contact the nearest Author-
ised Service Centre (the cool-
ing system will continue to
keep food products cold, but
temperature adjustment will
not be possible).
Close and open the door.
Contact the nearest Author-
ised Service Centre.
Refer to "Operation".
Wait few hours and then check
the temperature again.
Refer to climate class chart on
the rating plate.
Allow food products to cool to
room temperature before stor-
ing.
Refer to "Closing the door".
Refer to "Frostmatic function"
or "Coolmatic function".
Position the water drainage
plug in the correct way.
Refer to "Operation" .