Symptom/Error
I9990301
I9990302
I9990305
I9990303
Other codes not listed
above
FRU Codes
If an error is detected by the diagnostic tests, a four-digit
FRU code is displayed. The FRU code indicates two
suspected FRUs. Replace the FRU that is indicated by
the two leftmost digits first, then replace the FRU indicated
by the two rightmost digits . No FRU is assigned to code
00. If only one FRU is suspected, the other FRU code is
filled with zeros. See the referenced page before replacing
the FRU.
FRU Code
10
20
30
32
33
40
45
50
60
81
90
Note: The device ID and error codes are used to indicate
the detail portion of the FRU which caused the
error. If replacing a FRU does not correct a
problem, see the Device ID or error code from the
previous failure. If they have changed, the cause
might be because the new FRU is defective or that
the FRU was incorrectly installed.
If the problem remains after replacement of the FRUs, go
to "Undetermined Problems" on page 42.
FRU/Action
FRU/Action
System Board
Memory
(See "Memory Checkout" on page 26.)
Reserved
External Keyboard
External Mouse
LCD Assembly
External CRT
1. Reseat the Diskette Drive
2. Diskette Drive
1. Reseat the Hard Disk Drive
2. Hard Disk Drive
Internal Modem Card (if installed)
Reserved
ThinkPad 340x (IBM 2610)
1. Reseat the boot
device.
2. Check the startup
sequence for the
correct boot device.
3. Check that the
operating system has
no failures, and is
installed correctly.
1. System Board
1. Go to "Undetermined
Problems" on
page 42.
37