Numeric Error Codes
Symptom/Error
10X
110
111
161
163
(Time and Date was not
set.)
173
(Configuration data were
lost.)
174
(Perform "Checking the
Installed Devices List" on
page 46 before changing
any FRUs.)
184
(POP check sum error.)
190
(A depleted battery pack
was installed when the
power was on.)
191XX
199XX
1XX
2XX
FRU/Action
1. System Board
1. Go to "Memory
Checkout" on
page 26.
2. IC DRAM Card
3. System Board
1. Go to "Memory
Checkout" on
page 26.
2. System Board
1. Go to "Checking the
Backup Battery" on
page 31.
2. Backup Battery
3. System Board
1. Set Time and Date.
2. System Board
1. Select OK in the error
screen; then set time
and date.
2. Backup Battery
3. System Board
1. Check Device
Configuration.
2. System Board
3. Diskette Drive
Assembly
4. Hard Disk Drive
Assembly
1. Reset the POP in
Easy-Setup.
1. Go to "Checking the
Battery Pack" on
page 30.
1. System Board
1. System Board
1. System Board
1. Go to "Memory
Checkout" on
page 26.
2. IC DRAM Card
3. System Board
ThinkPad 340x (IBM 2610)