Troubleshooting Guide; Check Of The Iic Bus Lines - Panasonic TH-P42UT50D Service Manual

Plasma television
Table of Contents

Advertisement

7 Troubleshooting Guide

Use the self-check function to test the unit.
1. Checking the IIC bus lines
2. Power LED Blinking timing
7.1.

Check of the IIC bus lines

7.1.1.
How to access
7.1.1.1.
Self-check indication only:
Produce TV reception screen, and while pressing [VOLUME ( - )] button on the main unit, press [OK] button on the remote control
for more than 3 seconds.
7.1.1.2.
Self-check indication and forced to factory shipment setting:
Caution:
New key will be generated and previous TV programmes recorded in USB HDD will not be viewed. (See USB HDD
Recording) (Z only)
Produce TV reception screen, and while pressing [VOLUME ( - )] button on the main unit, press [MENU] button on the remote
control for more than 3 seconds.
7.1.2.
Screen display
7.1.3.
Check Point
Confirm the following parts if NG was displayed.
7.1.4.
Exit
Disconnect the AC cord from wall outlet or switch off the power with [ Power ] button on the main unit.
DISPLAY
Check Ref. No.
TUN
TU6705
STBY
IC8000
MEM1
IC8902
MEM2
IC8900
PANEL
IC9300
TEMP
IC2001
LAN
IC8650
ID2
BT
IC8000, A50
Description
TUNER
A-BOARD
PEAKS-LD4(STM)
A-BOARD
PEAKS EEPROM
A-BOARD
NAND FLASH
A-BOARD
PD6H
A-BOARD
TEMP SENSOR
A-BOARD
ETHERPHY
A-BOARD
A-BOARD
BLUETOOTH
A-BOARD/BLUETOOTH
18
Check Point

Advertisement

Table of Contents
loading

This manual is also suitable for:

Th-p42ut50mTh-p42ut50pTh-p42ut50sTh-p42ut50z