Diagnostics

7.1

LED displays

LED states in PROFINET mode
0 Device is switched off
1 Device is switched on and the in‐
2 Boot loader is started
3 Linux is started
4 MCP software is running, no PN
5 MCP software is running, PN com‐
6 MCP software is running, PN com‐
7 Error, e.g. incorrect configuration
*) LEDs in peripheral devices (keyboards, Powerrides and user keys connected to the digital outputs)
LED states in IE mode
0 Device is switched off
1 Device is switched on and the in‐
2 Boot loader is started
3 Linux is started
ONE MCP Part 1: MCP xxxx
Equipment Manual, 07/2020, A5E50324729B AA
State
ternal voltage is in the setpoint
range
communication
munication established, STOP
state
munication established, RUN state
or damaged USB peripheral
State
ternal voltage is in the setpoint
range
H1
H2
H4 PN
SYNC
FAULT
Off
Off
Off
Off
Off
Off
Off
On
Off
On
On
Off
Off
Off
On
On
Off
On
0.5 Hz
Off
On
4 Hz
4 Hz
4 Hz
H1
H2
H4 PN
SYNC
FAULT
Off
Off
Off
Off
Off
Off
Off
On
Off
On
On
Off
7
H5 IE
H3 PWR
PER *)
Off
Off
Off
Off
On
N/A
Off
On
N/A
Off
On
N/A
Off
On
1 Hz
Off
On
N/A
Off
On
N/A
4 Hz
On
4 Hz
H5 IE
H3 PWR
PER *)
Off
Off
Off
Off
On
N/A
Off
On
N/A
Off
On
N/A
53