Maintenance and Lubrication Schedule
Outer barrier and lower closure pivot points (2)
Outer barrier detent pin pivot points (2)
Inner roll stop hinge pivot points
Inner roll stop linkage pivot points
Lifting arm pivot points and rollers (bearings)
Inspect outer barrier and lower closure for proper
operation
750
Cycles
Inspect outer barrier seal and lower closure gasket
Inspect outer barrier detent pin hairpin cotter
Inspect lift for wear, damage or any abnormal
condition
Inspect lift for rattles
Check drive chain tension.
Apply Light Oil - See Lubrication Diagram
Apply Light Oil - See Lubrication Diagram
Apply Light Oil - See Lubrication Diagram
Apply Light Oil - See Lubrication Diagram
Apply Light Oil - See Lubrication Diagram
Correct or replace damaged parts.
Resecure, replace or correct as needed
Ensure hairpin cotter is present and can be removed
and inserted easily. Resecure, replace or correct as
needed.
Correct as needed.
Correct as needed.
Pull out and lock manual release cable. Adjust chain
tension as needed. See Drive Chain Adjustment.