Forced Operation - LG USNH1865NW0 Owner's Manual

Wall mounted
Table of Contents

Advertisement

ADVANCED FUNCTIONS
12

Forced operation

Forced operation is used when the remote controller can't be used. The operation will be started
if the ON/OFF button is pressed. If you want to stop the operation, re-press the button.
ON/OFF
button
Heat pump Model
Cooling Model
21°C ≤ Room Temp.
Room Temp.
Room Temp.
≥ 24°C
< 24°C
< 21°C
Operating mode
Cooling
Cooling
Healthy Dehumidification
Heating
Indoor FAN Speed
High
High
High
High
Setting Temperature
22 °C
22 °C
23 °C
24 °C
Test operation
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of
room temperature and resets in 18 minutes. During test operation, if remote controller signal is
received, the unit operates as remote controller sets. If you want to use this operation, Press and
hold the ON/OFF button for 3~5 seconds, then the buzzer sound 1 'beep'. If you want to stop the
operation, re-press the button.