Ip Address Configuration Setup Instructions; Factory Programmed Default Ip Address; Figure 12: Ethernet Status Leds - Location; Table 2: D9133Ttl-E Ethernet Status Led Function - Bosch D9133TTL-E Installation Manual

Network interface module
Table of Contents

Advertisement

.

Figure 12: Ethernet Status LEDs - Location

1 - Serial Port (Channel)1 Status
2 - Serial Port (Channel)2 Status
3 - Diagnostic
4 - Network Link Status

Table 2: D9133TTL-E Ethernet Status LED Function

LED
Function
1
NIM Software Version 4.5: On to indicate Serial Port
(Channel) 1 is idle.
NIM software version 5.1b5 or 5.1b6: Off to indicate
Serial Port (Channel) 1 is idle.
2
Not used.
Disregard status.
3
Glows steadily or flashes red in combination with the
Channel 1 LED to indicate diagnostics and error
detection.
LED 3 solid red, LED 1 (Channel 1) flashing red:
1x
EPROM checksum error
2x
RAM error
3x
Network controller error
4x
EEPROM checksum error
Duplicated IP address on the network*
5x
6x
Software does not match hardware
LED 3 Flashing red,
LED 1 (Channel 1) flashing red:
4x
Fault network connection*
5x
No DHCP response received*
4
On to indicate the network port is connected to the
network.
* Non-fatal error
Bosch Security Systems, Inc. | 6/07 | 4998122717-01
D9133TTL-E | Installation Guide | 5.0 IP Address Configuration Setup Instructions
2
1
3
4
The Network Interface Module (refer to Item
3, Figure 3 on page 5) software version
must be version 4.5 or higher. To verify the
software version, a Telnet session must be
initiated. Refer to Section 5.5 Using Telnet
to Finish the Configuration on page 11.
5.0 IP Address Configuration
Setup Instructions
The purpose is to set up the initial IP address so that
the D9133TTL-E can be set with a Network IP
address. The set up consists of using resident
commands and programs, i.e. the commands "ARP",
"Ping" and the program "Telnet" (the quotes used in
this explanation are not part of the command, they
are only used to identify the command string)
available in the Microsoft Windows
system.
A working knowledge of DOS commands,
®
Windows
, networks and their operation
are required.
5.1
Factory Programmed Default IP
Address
Bosch Security Systems, Inc. has programmed a
default IP address into the D9133TTL-E Serial
Interface.
The default IP address is not used for any
of the Bosch Security Systems, Inc.
functions. This information is supplied only
to assist the technician if a failure of the
ARP commands occurs. It might be useful
to know the default IP address should the
ARP commands fail. However, this
occurrence is highly unlikely. Contact
Technical Support at (800) 289-0096 if
you have further questions.
The D9133TTL-E ships with a default IP address of
192.168.000.002.
®