Table 1: D9133TTL-E Connection Sequence

Seq
Connection from
1
Ethernet RJ-45 Jack
2
SDI PWR
3
SDI A
4
SDI B
5
SDI COM
6
Battery – (Terminal 4)
7
Battery + (Terminal 5)
8
Terminal 1
9
Terminal 2
The D9133TTL-E address is set by placing and
removing jumpers from the "Address Pins" (refer to
Figure 3 on page 5 for location of Address Pins).
Figure 9 defines the current addresses that may be
used.
Figure 9:
SDI Address 88 – Alternate

Communication (Jumper 8 installed)

88
The D9133TTL-E address configuration is
read only at D9133TTL-E power-up. If the
address configuration is changed while the
D9133TTL-E is powered, a power reset
must be performed so that the
D9133TTL-E can reconfigure its address.
3.3

Ethernet Connections

The RJ45 Jack is used to connect to the D9133TTL-E to
the Ethernet Network (LAN/WAN). The connector
definitions are shown in Figure 10.

Figure 10: Ethernet Connector Pinouts

2
1
1 - TX +
2 - TX –
3 - RX +
6 - RX -
8
LEDs
Connected to
LAN or WAN
Power + (Terminal 32)
Data A (Terminal 31)
Data B (Terminal 30)
Common (Terminal 29)
Battery Negative (-)
Battery Positive (+)
AC Transformer
AC Transformer
1 2
4 8
3
6

4.0 LEDs

4.1

SDI LEDs

To enable the SDI LEDs, place the jumper across the
LED Enable Jumper.
The function of the LEDs and the Jumper is
described in Figure 11.

Figure 11: Diagnostic SDI LEDs and the LED

Enable Jumper

1 - BUS TX
2 - BUS RX
3 - SER TX
4 - SER RX
5 - Jumper P2
4.2

Ethernet/Serial Status LED

The D9133TTL-E has four Ethernet/Serial status
LEDs (refer to Figure 12 on page 9), three in the
center and one in the lower right corner next to the
RJ45 Modular Jack.
The LEDs on the D9133TTL-E are described in
Table 2 on page 9.
On power up, the three LEDs (LED 1, 2 and 3) are
on for one sec., LED 3 flashes four times, then
LED 1 and LED 2 turn on, and LED 3 turns off.
LED 4 stays on continuously as long as there is a
connection to the network.
If a Telnet session is established, LED 1 and LED 2
stay on; LED 3 toggles on and off.