Furuno FELCOM 15 Service Manual page 43

Inmarsat-c mobile earth station
Hide thumbs Also See for FELCOM 15:
Table of Contents

Advertisement

15) When starting the data report (F5-1).
16) When starting the self test for RF CON/CPU board (F7-7-3).
17) When starting the Distress Button Test (F7-7-4).
Information from RF CON/CPU board to TERM CPU board
1) When receiving the network information.
2) The information of the current channel type (NCSCC, LES TDM, MES Sig.CH, MES
Msg.CH and Retuning)
3) The description of the RX message (LES ID, Date, Priority, Size, Msg. Refe. No,.Sub
Add.)
4) EGC message
5) Login/out status
6) The information of tuning TDM Bulletin Board and SCD(signaling channel descriptor).
7) The number of the RX message in RF CON/CPU board.
8) BBER. Sends every 8.64 seconds.
9) The information of the current TDM information (Not Synchronized., NCSCC, LES
TDM, Joint NCSCC and TDM, and ST-BY NCSCC)
10) The information of the tuning NSC information
11) PV Test result
12) The transmitting result of the message (F6-1). (Sending, Success, Failed, Rejected,
Pending, Unknown)
13) The delivery information of the message (F3-3). (Msg. Refe No., Status, Attempts,
Failure Code and Add.)
14) MES status. (The information appeared in the display below.)
15) Displaying of the position data. Blinks if not updated within 4 hours.
16) Displaying of the WP data
17) Displaying of the self status (Updates every 5 seconds: BBER, C/N, Send Level, RX
AGC Level, REF Offset Freq., Syhnthe Local, Antenna Power Supply)
18) Displaying the result of the self test.
19) Caution command when the error occurs from RF CON/CPU board.
20) Polling data (F5-1)
2-21
2.3 Terminal unit, IC-215

Advertisement

Table of Contents
loading

Table of Contents