Preparation for use
3.2 Transporting and storage
3.2.1

Packaging specifications for air transportation

When transporting products containing permanent magnets by air, the maximum permissible
magnetic field strengths specified by the appropriate IATA Packing Instruction must not be
exceeded. Special measures may be required so that these products can be shipped. Above
a certain magnetic field strength, shipping requires that you notify the relevant authorities
and appropriately label the products.
Note
The magnetic field strengths listed in the following always refer to values for the DC
magnetic field specified in IATA packaging instruction 953. If the values change, we will take
this into account in the next edition.
Products whose highest field strength exceeds 0.418 A/m, as determined at a distance of
4.6 m from the product, require shipping authorization. This product will only be shipped with
previous authorization from the responsible national body of the country from where the
product is being shipped (country of origin) and the country where the airfreight company is
based. Special measures need to be taken to enable the product to be shipped.
When shipping products whose highest field strength is equal to or greater than 0.418 A/m,
as determined at a distance of 2.1 m from the product, you have a duty to notify the relevant
authorities and appropriately label the product.
When shipping products whose highest field strength is less than 0.418 A/m, as determined
at a distance of 2.1 m from the product, you do not have to notify the relevant authorities and
you do not have to label the product.
Shipping originally packed motor components neither has to be disclosed nor marked.
3.2.2

Ambient conditions for long-term storage and transport

Based on EN 60721-3-1 (for long-term storage) and EN 60721-3-2 (for transport)
Table 3- 4
Climatic ambient conditions
Lower air temperature limit:
Upper air temperature limit:
Lower relative humidity limit:
Upper relative humidity limit:
Rate of temperature fluctuations:
Condensation:
Formation of ice:
Long-term storage:
Transport:
Storage and transport are only permissible only in locations that are fully protected against the weather
(in halls or rooms).
54
- 5 °C (deviates from 3K3)
+ 40 °C
5%
85%
Max 0.5 K/min
Not permissible
Not permissible
Class 1K3 and class 1Z1 have a different upper relative humidity
Class 2K2
1FW6 external rotor built-in torque motors Operating
Instructions, 12/2020, A5E49196960B AB