directeur de l'OFR peut être contacté au 250-497-2300 (tél.)
ou au 250-497-2355 (fax). (Le Directeur des Normes
réglementaires d'Industrie Canada peut également être
contacté).
Certificate
8.6 Radio Equipment Directive (RED) 2014/53/EU
Rosemount 1408H complies with ETSI EN 302 372 (TLPR) and EN
62479.
For the receiver test that covers the influence of an interferer signal to
the device, the performance criterion has at least the following level
of performance according to ETSI TS 103 361 [6].
•
Performance criterion: measurement value variation Δd over time
during a distance measurement
•
Level of performance: Δd ≤ ± 2 mm
TLPR (Tank Level Probing Radar)
•
The device must be installed in closed tanks. Install according to
requirements in ETSI EN 302 372 (Annex E).
8.7 Additional certifications
®
8.7.1 3-A
Certificate
Authorization
Number
Standard
20
2827A-1408T
3626
3-A Sanitary Standards for Number 74-07
(Sensors and Sensor Fittings and Connections)