PROBLEM
Tank Level indicator displays
"Reading" constantly and/or
no tank level reading being
indicated
Alert beeping for 5 seconds
every minute and LCD bar
blinking at fuel level guage
indicator
Meat Probe temperature
indicates 32 degress F or 0
degrees C.
Tank level indicates "reading"
continuously and does not
change or give tank level
reading
TROUBLESHOOTING GUIDE
POSSIBLE CAUSES
•Natural Gas model
•Propane cylinder not installed
•Propane cylinder not installed
properly into tank caddy
•loose tank sensor wire
•propane fuel level low +/-10%
remaining
•Meat probe wire damaged
•tank sensor wire installed
incorrectly
SOLUTIONS
•Natural Gas models do not utilize this function, gas
is constant and always full in NG models.
•install Propane cylinder - refer to your "Outdoor
Gas Barbecue/Grill assembly Manual/Use & Care"
for instructions
•Check that propane cylinder is installed and
inserted into tank caddy as shown in manual and
that it is sitting completely upright. Improper
assembly and installation will result in improper
readings for your propane level. For the tank level
indicator to work as desired, tank bottom should be
clean and free of rust, debris, or sharp edges.
Without a clean positive contact the tank level
indicator may not pick up readings or will give
improper readings. If no reading or improper
reading, please ensure that the tank bottom and
tank sensor button are cleaned before placing tank
back into position.
•note: this barbecue is designed to be used only
with a 20lb (9.1kg) propane cylinder
•check firm connection point to tank sensor
connector, connector will "click" into position when
completely inserted
•replace propane cylinder with full propane cylinder,
refer to your "Outdoor Gas Barbecue/Grill assembly
Manual/Use & Care" for instructions
•Replace meat probe with Original Mfg. Meat probe
- contact customer service for replacement partsFor
additional troubleshooting
•check connection and install correctly

Advertisement

Table of Contents