5. TROUBLESHOOTING

The Chart shows the most frequent breakdowns , possible causes and relative remedies:
PROBLEM DESCRIPTION
The appliance does not come on
The refrigerator unit does not start Set temperature is reached
The refrigerator is continuously
working but does not reach the set
temperature
Refrigerator does not stop at set
temperature
Ice blocks on evaporator
Appliance is noisy
Safety DC fan does not work
POSSIBLE CAUSE
The main switch is "off"
There is no tension
Other
Defrosting is in operation
Control Panel is broken
Other
Room is too hot
Condenser is dirty
Refrigerant fluid is insufficient
Condenser fan has stopped
Door not properly closed
Evaporator is frosted up
Defrost valve is open
Control Panel is broken
Temperature probe is broken
Door is not airtight
Improper use
Control Panel is broken
Appliance not levelled
Contact with external bodies
Screws or nuts loose
Other
Fan disconnected
Stuck fan
Fan motor damaged
31
SOLUTION
Main switch "on"
Check plug, socket, electric connection
Contact technical assistance
Set new temperature
Wait for end of cycle, switch off and switch back
on
Contact technical assistance
Contact technical assistance
Air better
Clean condenser
Contact technical assistance
Contact technical assistance
Check door seals
Manual defrosting
Contact technical assistance
Contact technical assistance
Contact technical assistance
Close door
Contact technical assistance
Contact technical assistance
Check that appliance is level.
Check that no tube or ventilator fan is in contact
with external bodies.
Tighten
Contact technical assistance
Re-wire the fan to the electrical strip contact
Replace the fan
Replace the fan