130 4280 010 E
DN100-150 Flanged Body Models
Close the upstream shutoff cock and disconnect power to the actuator.
CAUTION: Personal injury hazard. The valve cover contains a compressed spring. Improper
disassembly could cause the valve cover and spring to fly off resulting in personal injury or equipment
damage.
Unscrew the sealed locking screw from the bottom valve cover and replace it with a centering disk
(disk to DIN 9021- 8,4 or JCI part number 130 2069 010) and screw M 6, see Table 4 and Figure 4.
Tighten the screw three turns past the stop so that the valve seat plug lifts off the valve seat, securing
the valve spring.
Remove the valve cover mounting screws.
Remove the valve cover, valve spring, valve seat plug, and filter. Refer to Figure 4 for part identification.
Clean or replace valve seat plug and seal, filter, and gasket.
Check the surface of the valve seat plug. If the seat plug is damaged in anyway, replace it. Contact
Johnson Controls for replacement part numbers.
Ensure that the valve seat plug bore is free of foreign matter before installing it on the valve stem. Re-
insert valve seat plug, filter, and gasket.
Place the valve spring inside the valve body and secure it with the valve cover and two opposing
mounting screws. Ensure that the valve seat plug is not tilted.
Insert the other two mounting screws. Ensure that the valve body and cover are sealed. For torque refer
to Table 3.
Remove the screw and centering disk inserted and replace it with the locking screw. For torque refer to
Table 3. The locking screw has to be sealed.
Open the upstream shutoff cock and check for leakage along the valve cover. (Refer to the Checkout
Procedure section).
Observe at least three complete operating cycles to ensure that all components are functioning correctly.
Johnson Controls SA/NV - Leuvensesteenweg 248D - B-1800 Vilvoorde - +32(2) 709 40 00 - www.johnsoncontrols.be
Page:14
Valve Model
DN100 Flanschventil GH-54..
DN125 Flanschventil GH-54..
DN100-150 Flanschventile GH-57..
DN150 Flanschventil GH-54..
Table 4: Bolt dimensions
Bolt
M6 x 55
M6 x 60
M6 x 70