NOTE
Refer to Splice Module installation
instructions for the length required inside the
cabinet. Ensure sufficient sheathed cable
exists at the top of the sealing grommet to
install shield connectors.
i. Using a wrench to hold the sealing grommet
steady, use a second wrench to tighten the
compression nut until the compression skirt
creates a weathertight seal around the cable.
II. SHIELDING
On non-stubbed cabinet installations the shield and
braid must be connected to the ground buss as
described in this procedure. Refer to Figure 12 for
views of the connector components, cable, and
assembly sequence. Entry cables have an outer
insulator, a shield sheath, and a core wrap protecting
the inner wire bundle, see View A. The shield sheath
must connect to ground with the supplied connectors
and ground braid.
The connectors and ground braid are temporarily
attached at the factory for cabinet shipment, remove
the connectors from the braid for this procedure.
CAUTION
Ensure wire insulation is not damaged during
shield connection.
a. From where the wire bundle exits the cable,
remove about 3/4 inch of insulation and shield
but leaving the protective core wrap intact. See
view B for steps a and b.
b. On the side opposite from where the shield
connector will be placed, make a one inch slice
through the insulator and the shield but not the
core wrap. This eases the insertion of the
connector.
c. Opposite the slice, insert the connector bottom
into the cable between the shield and the core
wrap until it reaches the small stop tabs. See
view C for steps c and d.
d. Tap the cable in the area of the leading edge of
the connector to set the contact teeth into the
shield
e. Slide the connector top over the stud so it
sandwiches the shield and insulator. Install the
1 0
first nut and tighten until the connector securely
grips the shield and insulator. See view D.
f. Install the ground braid over the stud followed
by the second nut and tighten securely. See view
E. Repeat this process for the remaining cable.
g. Ensure the trailing end of the ground braid is
securely connected to the ground buss.
Connector
Bottom
A
B
C
D
E

Figure 12. Shield Connector Assembly

Section 61150090L1-5A, Issue 1
Connector Top
Wire
Core
Shield
Bundle
Wrap
Securing Nuts (2)
Insulator
Shield &
Insulator
61150090L1-5A