ADTRAN T200 H2TU-R Installation And Maintenance Manual
ADTRAN T200 H2TU-R Installation And Maintenance Manual

ADTRAN T200 H2TU-R Installation And Maintenance Manual

High capacity cabinet
Hide thumbs Also See for T200 H2TU-R:

Advertisement

Quick Links

CONTENTS
1. GENERAL ..................................................................... 1
2. INSTALLATION ............................................................ 4
3. TESTING ..................................................................... 15
4. MAINTENANCE ......................................................... 18
5. WARRANTY AND CUSTOMER SERVICE .............. 20
FIGURES
Figure 1. High-Capacity T200/T400 Cabinet
(Pad Mount Model) ........................................... 1
Figure 2. Cabinet Assembly, Rear View ............................ 3
Figure 3. Top View Cutaway With Installation
Measurements .................................................... 3
Figure 4. Pad Mount Dimensions ...................................... 5
Figure 5. Lifting Detail Assembly ..................................... 5
Figure 6. Pad Mounting Bracket Installation .................... 6
Figure 7. Pole Mount Dimensions ..................................... 6
Figure 8. Mounting Bracket Assembly .............................. 7
Figure 9. Bottom Support Bracket Assembly .................... 8
Figure 10. Guide for Pole Mounting .................................. 8
Figure 11. Sealing Grommet Assembly .............................. 9
Figure 12. Shield Connector Assembly ............................ 10
Figure 13. Primary & Secondary Fan Boards .................. 15
Figure 14. Surge Arrestor Board ....................................... 18
Figure 15. Surge Arrestor Gas Tube Replacement .......... 18
Figure 16. Door Switch .................................................... 20
TABLES
Table 1. T200/T400 Cabinet Basic Features ..................... 2
Table 2. Pad Mounting Hardware ..................................... 5
Table 3. Pole Mount Hardware ......................................... 7
Table 4. Seal Grommet Kit ................................................ 9
Table 5A. Splice Module 1 ................................................ 12
Table 5B. Splice Module 2 ................................................ 12
Table 6A. Circuit Technology Configuration
Chart (Part 1) ..................................................... 13
Table 6B. Circuit Technology Configuration
Chart (Part 2) ..................................................... 14
Table 7. Replacement Item Part Numbers ....................... 18
Table 8. Customer & Circuit Information ....................... 21
1. GENERAL
This practice provides installation and maintenance
procedures for the ADTRAN High-Capacity
Trademarks: Any brand names and product names included in this document are
61150090L1-5A
trademarks, registered trademarks, or trade names of their respective holders.
High Capacity T200/T400 Cabinet
Installation and Maintenance
Section 61150090L1-5A, Issue 1
List 1: CLEI CODE # T1MJ4U0MRA
List 2: CLEI CODE # T1MJ5U0MRA
List 3: CLEI CODE # T1MJ4V0MRA
List 4: CLEI CODE # T1MJ5V0MRA
Figure 1. High-Capacity T200/T400 Cabinet
(Pad Mount Model)
T200/T400 Cabinet. Figure 1 is an illustration of the
unit. Four models are available.
The part numbers and basic features of each cabinet
model are provided in Table 1. The cabinet is a high-
capacity T200/T400 enclosure which supports the
demand for numerous circuits spread over small areas.
Revision History
This is the first issue of this document. Future
revisions will be described in this paragraph.
Practice Review
This Practice contains important pre-installation
information. Craft personnel should review Sections 1
and 2 of this Practice as part of installation planning.
Description
The ADTRAN T200/T400 High Capacity Cabinet is
an outdoor, above-ground enclosure. Up to 24
Section 61150090L1-5
Issue 1, April 1999
1

Advertisement

Table of Contents
loading

Summary of Contents for ADTRAN T200 H2TU-R

  • Page 1 This Practice contains important pre-installation information. Craft personnel should review Sections 1 and 2 of this Practice as part of installation planning. Description The ADTRAN T200/T400 High Capacity Cabinet is an outdoor, above-ground enclosure. Up to 24 Section 61150090L1-5A, Issue 1 Section 61150090L1-5...
  • Page 2 ADTRAN Line Powered T200 or T400 Circuit Packs can be installed per cabinet. The cabinet system is pre- wired with surge arrestor boards to reduce installation and turn-up time. Wiring consists of either pre-wired cable stubs or pre-wired internal splice module connections depending on the model.
  • Page 3: Figure 2. Cabinet Assembly, Rear View

    Door Ground Braid Gas Tube Extractor Pliers Figure 2. Cabinet Assembly, Rear View OPEN 23" Front door 20 7/16" View is looking down with top cut away. Mounting bolt hole center lines are 1 5/8" in from each edge. Ground stud is 1 5/8" from rear edge. Measurements shown are center to center (C/C).
  • Page 4: Installation

    After unpacking the T200/T400 High Capacity Cabinet inspect it for damage. If damage is noted file a claim with the carrier, then contact ADTRAN Customer Service (refer to Section 5). Never install telephone wiring during a lightning storm.
  • Page 5: Figure 4. Pad Mount Dimensions

    the bracket pattern. Refer to Figure 4 for pad mount access dimensions. 1. At the installation site remove all packaging material enclosing the cabinet. 2. Remove and set aside the mounting hardware kit. Verify contents per Table 2. 3. The cabinet is bolted to two boards running across the box frame.
  • Page 6: Figure 6. Pad Mounting Bracket Installation

    nut* split washer* flat washer* Mounting Pad mounted stud* Bracket (4 places) *Customer supplied Pad arrangement is representative Figure 6. Pad Mounting Bracket Installation 9. Hoist the cabinet to an upright position and center it over the pad. CAUTION The minimum internal bend radius for cable stubs is nine inches.
  • Page 7: Figure 8. Mounting Bracket Assembly

    Table 3. Pole Mount Hardware t f i t f i ) l i " 1 s t l t i l t f i 4. Attach lifting details. Screwed into each side of the cabinet is a group of three bolts and washers. Remove these for reuse.
  • Page 8: Figure 9. Bottom Support Bracket Assembly

    (customer supplied) instead of lag screws for attaching the bottom pole mount support brackets to the H-frame. ADTRAN recommends the use of steel cross bars between the two poles to ensure adequate strength. The H-frame facility must be able to bear the weight of a fully-equipped cabinet (200 Lbs).
  • Page 9: Figure 11. Sealing Grommet Assembly

    CAUTION Ensure all grounds are securely connected to the cabinet ground buss and the ground lug connected to the most direct path to ground. The following procedures describe wiring connections for both the stubbed and module connection models: 1. Unscrew the security screws on the front and rear doors using a 7/16 inch nut driver or equivalent tool.
  • Page 10: Figure 12. Shield Connector Assembly

    NOTE Refer to Splice Module installation instructions for the length required inside the cabinet. Ensure sufficient sheathed cable exists at the top of the sealing grommet to install shield connectors. i. Using a wrench to hold the sealing grommet steady, use a second wrench to tighten the compression nut until the compression skirt creates a weathertight seal around the cable.
  • Page 11 III. SHRINK-WRAP After all other connections are completed, or correct wire lengths verified, complete the shrink-wrap process as follows: a. Position the shrink-wrap up against the bottom of the cabinet enclosing the entire sealing grommet assembly. b. Heat treat the shrink-wrap until properly constricted around the assembly.
  • Page 12: Table 5A. Splice Module 1

    Table 5A. Splice Module 1 e t i e u l e t i e t i e t i e t i e t a e u l e t a e u l e t a l l e e u l l l e l l e...
  • Page 13 61150090L1-5A Section 61150090L1-5A, Issue 1...
  • Page 14 Section 61150090L1-5A, Issue 1 61150090L1-5A...
  • Page 15: Testing

    3. TESTING General Each test identifies a particular malfunction. For that reason associated components used to isolate a malfunction are assumed to be functioning correctly. Certain troubleshooting requires personnel at both the Central Office to monitor the FPU, and field personnel at the cabinet to determine if a fault condition exists.
  • Page 16 3. Disable the front door switch by centering the rod and pulling outward. The secondary fan board Door LED should go Off and the Door Alarm LED at the FPU will turn green. Fan Operation When the cabinet is initially installed without heat generating circuit packs, the primary and secondary fans will not automatically turn On.
  • Page 17 If the cabinet has been opened during the day allowing the heat to escape before proper troubleshooting tests could be conducted, close the cabinet doors and allow the cabinet internal temperature to restabilize. Recheck during the hottest time of the following day before the outside temperature has a chance to drop.
  • Page 18: Maintenance

    Fan board repairs should not be attempted in the field. Repair services are obtained by returning the defective unit to ADTRAN Customer Service. Refer to Table 7 for a list of replacement item part numbers.
  • Page 19 6. Perform circuit tests to verify proper circuit operation. NOTE If lightning is the suspected cause of circuit pack failure, ADTRAN recommends replacing all the surge arrestor gas tubes. Door Gasket Replacement The door gasket provides a weathertight seal. Routine preventive maintenance includes cleaning the seal and seal area when the cabinet door is opened.
  • Page 20: Warranty And Customer Service

    Table can be updated when circuits are connected or changed. 5. WARRANTY AND CUSTOMER SERVICE ADTRAN will replace or repair this product within five years from the date of shipment if it does not meet its published specifications or fails while in...
  • Page 21: Table 8. Customer & Circuit Information

    Table 8. Customer & Circuit Information 61150090L1-5A Section 61150090L1-5A, Issue 1...

This manual is also suitable for:

T200T400