US/CA
8.1.2 INSTALLER SETTINGS: Heating parameters
Menu structure
Heating parameters
Heating circuit type
Base line
Design Temp
Design supply temp.
Maximum heating supply
temperature
Room influence
Room influence enabled for
modes
Room temperature offset
Heating OFF until lower level
reached
Heating OFF at outdoor
temperature
Risk of freezing at outdoor
temperature
Mixer run time
Minimum outdoor temperature
Building storage capacity
Calibrate internal room temp
sensor
Heating circuit solar
1)
optimization
1) Only with ISM
8.1.3 INSTALLER SETTINGS: Fault history
Menu structure
Fault history
01/01/2010
04:11pm
EA Boiler
(example for last fault)
09/25/2010
06:45pm
32 IPM ID 10
(up to maximum of 19 past
faults)
Menu settings INSTALLER SETTINGS (for installers only) | 33
Default
setting
Control range
Radiators
Baseline/Design temp | Radiant
Floor | Radiators | Baseboard
78 °F (25 °C)
50 °F ... 186 °F (10 °C ... 85 °C)
168 °F (75 °C) 86 °F ... 186 °F (30 °C ... 85 °C)
168 °F (75 °C) 86 °F ... 186 °F (30 °C ... 85 °C)
176 °F (80 °C) 86 °F ... 186 °F (30 °C ... 85 °C)
30%
0% ... 100%
Eco/Frost
Eco/Frost | Comfort/Eco/Frost
0 °F (0.0 °C)
– 9 °F ... 9 °F
( – 5.0 °C ... 5.0 °C)
Yes
No | Yes
68 °F
50 °F ... 77 °F
(20.0 °C)
(10.0 °C ... 25.0 °C), 210 °F
(99.0 °C) (= function off)
38 °F (3.0 °C) 23 °F ... 50 °F
( – 5.0 °C ... 10.0 °C)
140 s
10 s ... 600 s
5 °F ( – 15 °C) – 22 °F ... 32 °F
( – 30 °C ... 0 °C)
50%
0% ... 100%
0.0 °F (0.0 °C)
– 5.4 °F ... 5.4 °F
( – 3.0 °C ... 3.0 °C)
0 °F (0 °C)
0 °F (= function off) ... 9 °F
(0 °C ... 5 °C)
Default
setting
Control range
–
–
–
–
Personal
Description
setting
starts on page
35
°F ( °C)
37
°F ( °C)
37
°F ( °C)
37
°F ( °C)
37
%
37
37
°F ( °C)
38
38
°F ( °C)
38
°F ( °C)
38
s
38
°F ( °C)
39
%
39
°F ( °C)
39
°F ( °C)
39
Description
Personal
starts
setting
on page
–
–
40
6 720 643 259 (2010/05)